12.2 Alarm Displays
12.2.2 Troubleshooting Alarms
12-36
A.d01:
Position Devia-
tion Overflow
Alarm at Servo
ON
The servo was turned
ON after the position
deviation exceeded
the setting of Pn526
(Excessive Position
Deviation Alarm Level
at Servo ON) while the
servo was OFF.
Check the position
deviation while the
servo is OFF.
Set the position deviation
to be cleared while the
servo is OFF.
Optimize the setting of
Pn526 (Excessive Position
Deviation Alarm Level at
Servo ON).
A.d02:
Position Devia-
tion Overflow
Alarm for Speed
Limit at Servo ON
If position deviation
remains in the devia-
tion counter, the set-
ting of Pn529 or
Pn584 (Speed Limit
Level at Servo ON)
limits the speed when
the servo is turned
ON.
This alarm occurs if
reference pulses are
input and the setting
of Pn520 (Excessive
Position Deviation
Alarm Level) is
exceeded.
–
Set the position deviation
to be cleared while the
servo is OFF.
Optimize the setting of
Pn520 (Excessive Position
Deviation Alarm Level).
Or, adjust the setting of
Pn529 or Pn584 (Speed
Limit Level at Servo ON).
A.d10:
Motor-Load Posi-
tion Deviation
Overflow
The motor direction
and external encoder
installation orientation
are backward.
Check the motor direc-
tion and the external
encoder installation ori-
entation.
Install the external
encoder in the opposite
direction, or change the
setting of Pn002 =
n.X
(External
Encoder Usage) to
reverse the direction.
There is an error in the
connection between
the load (e.g., stage)
and external encoder
coupling.
Check the coupling of
the external encoder.
Check the mechanical
coupling.
–
A.d30:
Position Data
Overflow
The position data
exceeded
±
1,879,048,192.
Check the input refer-
ence pulse counter.
Reconsider the operating
specifications.
–
A.E72:
Feedback Option
Module Detec-
tion Failure
There is a faulty con-
nection between the
SERVOPACK and the
Feedback Option
Module.
Check the connection
between the SERVO-
PACK and the Feed-
back Option Module.
Correctly connect the
Feedback Option Module.
–
The Feedback Option
Module was discon-
nected.
–
Reset the Option Module
configuration error and
turn the power supply to
the SERVOPACK OFF and
ON again.
A failure occurred in
the Feedback Option
Module.
–
Replace the Feedback
Option Module.
–
A failure occurred in
the SERVOPACK.
–
Replace the SERVO-
PACK.
–
Continued from previous page.
Alarm Number:
Alarm Name
Possible Cause
Confirmation
Correction
Reference
for Correc-