8.9 Anti-Resonance Control Adjustment
8.9.5 Related Parameters
8-54
6.
When the adjustment has been completed, click the
Finish
Button.
The values that were changed will be saved in the SERVOPACK and you will return to the Tuning Dia-
log Box.
This concludes the procedure.
8.9.5
Related Parameters
The following parameters are automatically adjusted or used as reference when you execute
anti-resonance control adjustment.
Do not change the settings while anti-resonance control adjustment is being executed.
Yes: The parameter is automatically set.
No: The parameter is not automatically set, but the setting is read during execution.
Parameter
Name
Automatic Changes
Pn160
Anti-Resonance Control-Related Selections
Yes
Pn161
Anti-Resonance Frequency
Yes
Pn162
Anti-Resonance Gain Correction
No
Pn163
Anti-Resonance Damping Gain
Yes
Pn164
Anti-Resonance Filter Time Constant 1 Correction
No
Pn165
Anti-Resonance Filter Time Constant 2 Correction
No