6.5.5 /V-CMP (Speed Coincidence Detection) Signal
6-26
•
Linear Servomotors
The signal is output when the difference between the reference speed and motor speed is
equal or less than the setting.
Pn582
Speed Coincidence Signal Detection Width
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
0 to 100
1 mm/s
10
Immediately
Setup
If Pn582 is set to 100 and the speed reference is 2,000 mm/s the signal would be output
when the motor speed is between 1,900 and 2,100 mm/s.
Speed
Example
Pn582
S
peed reference
The /V-CMP
s
ignal i
s
output when the motor
s
peed i
s
in
the area between the dotted line
s
.
Motor
s
peed