7.4 Trial Operation from the Host Controller for the Servomotor without a Load
7.4.1 Preparing the Servomotor for Trial Operation
7-11
7
T
rial Operation and Actual Operation
7.4.1
Preparing the Servomotor for Trial Operation
This section provides the procedure to prepare the Servomotor for trial operation.
Preparations
Confirm the following items before you perform the procedure to prepare the Servomotor for
trial operation.
•
Make sure that the preparations given in
completed.
•
Make sure that the trial operation described in
7.3 Trial Operation for the Servomotor without
on page 7-7 has been completed.
Operating Procedure
The following procedure assumes that the default settings are used for the I/O signals required
for trial operation. Refer to the following section for information on the default I/O signal set-
tings.
1.
Wire the I/O signals from the host controller.
Refer to the following section for details.
2.
Check the following items.
Make sure that the /S-ON (Servo ON) signal can be input.
Make sure that the P-OT (Forward Drive Prohibit) and N-OT (Reverse Drive Prohibit)
signals are ON (closed).
Setting Procedure
•
Input the signal to turn ON CN1-42 and CN1-43 (closed).
•
Set Pn50A to n.8
(Set the signal to always enable forward drive) and Pn50B to
n.
8 (Set the signal to always enable reverse drive).
Make sure that a reference is not being input.
CAUTION
Before you perform trial operation of the Servomotor without a load for references from the
host controller, make sure that there is no load connected to the Servomotor (i.e., that all
couplings and belts are removed from the Servomotor) to prevent unexpected accidents.
To power
s
upply
CN1, to ho
s
t controller
S
ecure the motor flange to the
machine. Do not connect the
motor
s
haft to the load