3.6 Main Circuit Wiring
YASKAWA ELECTRIC
TOEP C710656 07A YASKAWA Power Regenerative Converter - D1000 Instruction Manual
63
El
ec
tr
ical
I
n
st
al
lat
ion
3
4A0270
R/L1,S/L2,T/L3
60
×
2P
60 to 150
300
×
2P
300
95
×
2P
95 to 150
M12
32 to 40
(283 to 354)
–, +
100
×
2P
100 to 150
300
×
2P
300
95
×
2P
95 to 150
M12
32 to 40
(283 to 354)
r1/ 11, 1/ 21,
t1/ 31
2
2 to 5.5
14
14 to 10
2.5
2.5 to 6
M4
1.1 to 1.2
(9.7 to 10.6)
60
60 to 100
2/0
2/0 to 4/0
95
70 to 95
M12
32 to 40
(283 to 354)
4A0370
R/L1,S/L2,T/L3
100
×
2P
100 to 150
4/0
×
4P
4/0 to 300
150
×
2P
150
M12
32 to 40
(283 to 354)
–, +
100
×
4P
100 to 150
4/0
×
4P
4/0 to 300
150
×
2P
150
M12
32 to 40
(283 to 354)
r1/ 11, 1/ 21,
t1/ 31
2
2 to 5.5
14
14 to 10
2.5
2.5 to 6
M4
1.1 to 1.2
(9.7 to 10.6)
60
×
2P
60 to 150
4/0
2/0 to 300
150
70 to 150
M12
32 to 40
(283 to 354)
4A0630
R/L1,S/L2,T/L3
100
×
4P
100 to 150
4/0
×
8P
4/0 to 300
150
×
4P
150
M12
32 to 40
(283 to 354)
–, +
150
×
4P
150
4/0
×
8P
4/0 to 300
120
×
4P
120 to 150 M12
32 to 40
(283 to 354)
r1/ 11, 1/ 21,
t1/ 31
2
2 to 5.5
14
14 to 10
2.5
2.5 to 6
M4
1.1 to 1.2
(9.7 to 10.6)
60
×
2P
60 to 150
250
2/0 to 300
150
×
2P
70 to 150
M12
32 to 40
(283 to 354)
<1> Gauges listed here are for use in Japan.
<2> Gauges listed here are for use in the United States.
<3> Gauges listed here are for use in Europe and China.
Model
Terminal
For Asia
<1>
For U.S.A.
<2>
For Europe and China
<3>
Screw
Size
Tightening
Torque
N
x
m
(lb
x
in.)
Recommended
Gauge
mm
2
Applicable
Gauge
mm
2
Recommended
Gauge
AWG
Applicable
Gauge
AWG
Recommended
Gauge
mm
2
Applicable
Gauge
mm
2