Setting User Constants
4.2.3 User Constant Access Levels
- 8
Setting a User Constant in the Quick-start Access Level
The user constant level will be displayed when the DATA/ENTER Key is pressed at the programming
mode display.
Use the following display to set the acceleration time to 20.0 s.
Step
Key Sequence
Digital Operator Display
Remarks
1
MENU
MC5
Main Menu
Operation
2
Press twice.
MC5
Main Menu
Programming
3
DATA
ENTER
Reference source
Terminals
Changed to constant setting level.
4
Run Source
Terminals
5
Stopping Method
Ramp to Stop
6
Accel Time 1
C1
--
01 = 10
.
0 Sec
7
DATA
ENTER
Accel Time 1
0010
.
0 Sec
Selects the user constant so that the
leading 0 blinks. The digit that is
blinking can be changed.
8
RESET
Press twice.
Accel Time 1
0010
.
0 Sec
Blinking digit moves 2 places to the
right.
9
Accel Time 1
0020
.
0 Sec
Changes 1 to 2.
10
DATA
ENTER
Entry Accepted
Accel Time 1
C1
--
01 = 20
.
0 Sec
After approx. 3 seconds, the Operator
display is as shown on the left.
The acceleration time has been set to 20.0 seconds.
Step
Key Sequence
Digital Operator Display
Remarks
11
ESC
MC5
Main Menu
Programming
Returns to programming mode display.
4
A
EXAMPLE
"