2.4
Installation Orientation and Space
- 7
2.4
Installation Orientation and Space
Install the Inverter on a vertical surface so as not to reduce the cooling effect. When installing the Inverter, al-
ways provide the following installation space to allow normal heat dissipation.
(
a
) Horizontal Space
50 mm min.
30 mm min. 30 mm min.
50 mm min.
(
b
) Vertical Space
120 mm min.
120 mm min.
Air
Air
Fig
2.1
VS-626MC5 Installation Orientation and Space
S
The same space is required horizontally and vertically for both open chassis (IP00) and enclosed
wall-mounted (IP20, NEMA 1) Inverters.
S
Always remove the protection covers before installing a 200 or 400 V Class Inverter with an output
of 15 kW or less in a panel.
S
Always provide enough space for suspension eye bolts and the main circuit lines when installing a
200 or 400 V Class Inverter with an output of 30 kW or more in a panel.
2
IMPORTANT