6-2
175932-1CD
175932-1CD
EcoTrim ET-1024 System
6 Anchor Requirements
WORK-CELL
FENCE POSTS
3/8-inch Kwik Bolt II
Style Anchor
Not Applicable
3-inch minimum thickness or
1.3 embedment depth
(whichever is larger)
4000 psi Reinforced Concrete
OPERATOR
STATION PEDESTAl
1/4-inch Kwik Bolt II
Style Anchor
Not Applicable
3-inch minimum thickness or
1.3 embedment depth
(whichever is larger)
4000 psi Reinforced Concrete
NOTES:
(1) Minimum robot lagging requirements are based on maximum repulsion forces and the
Hilti
®
Anchor
Design Program
(v3.3b).
(2) SP-series robots require base plates and/or risers to be level within ± 2°. Grout if necessary.
(3) Reference source:
Hilti
®
Product Technical Guide
(section 4.2.1) for hardware specifications or
equivalent.
(4) Reference source:
Hilti
®
Product Technical Guide
(section 4.3.3) for hardware specifications or
equivalent.
(5) Robot manual requirements calling for cast-in anchors may be substituted with the recommendations
listed.
http://us.hilti.com
for further information.
Table 6-1: Minimum Recommended Equipment Anchor Requirements
EQUIPMENT
MINIMUM HILTI
®
ANCHOR ROD
DIAMETER/TYPE
MINIMUM FLOOR-PLATE
REQUIREMENTS
MINIMUM FOUNDATION
REQUIREMENTS
55 of 64