STARTER MOTOR
10-18
6LPA Service Manual
Starter
© 2007 Yanmar Marine International
No Load Performance Test
1. Connect the battery (Figure 10-47, (1)) and
ammeter (Figure 10-47, (2)) to the starter.
2. Check that the starter rotates smoothly and that
the pinion gear moves outwards.
3. Check current using ammeter. If ammeter
reading is not within specifications, check for
mechanical drag or component damage of
failure.
Standard no load current:
• 12V Type - 180A or less at 11.0V
• 24V Type - 90A or less at 24.0V
Figure 10-47
Figure 10-47
00054
3
5
(1)
(2)
Содержание 6LPA-STP2
Страница 1: ...6LPA series 6LPA Service Manual SERVICE MANUAL 6LPA STP2 6LPA STZP2 P N 0B6LP G00100 MARINE ENGINES ...
Страница 157: ...ENGINE 6LPA Service Manual 5 77 Timing Belt 12 05 2007 Yanmar Marine International This Page Intentionally Left Blank ...
Страница 178: ...FUEL SYSTEM 6 2 6LPA Service Manual 2007 Yanmar Marine International This Page Intentionally Left Blank ...
Страница 214: ...COOLING SYSTEM 7 2 6LPA Service Manual 2007 Yanmar Marine International This Page Intentionally Left Blank ...
Страница 230: ...LUBRICATION 8 2 6LPA Service Manual 2007 Yanmar Marine International This Page Intentionally Left Blank ...
Страница 248: ...TURBOCHARGER 9 2 6LPA Service Manual 2007 Yanmar Marine International This Page Intentionally Left Blank ...
Страница 268: ...TURBOCHARGER 9 22 6LPA Service Manual Turbocharger 2007 Yanmar Marine International This Page Intentionally Left Blank ...
Страница 270: ...STARTER MOTOR 10 2 6LPA Service Manual 2007 Yanmar Marine International This Page Intentionally Left Blank ...
Страница 288: ...ALTERNATOR 11 2 6LPA Service Manual 2007 Yanmar Marine International This Page Intentionally Left Blank ...
Страница 308: ...TROUBLESHOOTING 12 2 6LPA Service Manual 2007 Yanmar Marine International This Page Intentionally Left Blank ...