Страница 1: ...cy Body Composition Analyzer Body Planner DF870 Operation Manual Yamato Scale Co Ltd Carefully read this operation manual and the product warranty to use this product properly Keep this manual for future reference ...

Страница 2: ...sing care as well as fitness since it can indicate the body fat percentage and visceral fat index which serve as barometers of health in addition to SMI and other information which is used as a guide to maintain muscles The DF870 also allows you to control your health on your smartphone by scanning a generated QR code Thoroughly read this operation manual to use Body Planner DF870 in an optimum co...

Страница 3: ...r 24 3 6 Personal correction function 25 Chapter 4 User menu 26 4 1 How to call the User menu screen 26 4 2 Time setting 26 4 3 Operation setting Parameter list 27 4 4 Descriptions about parameters 28 4 5 Number of measurements 29 Chapter 5 Connection to external devices 30 5 1 Connection to a smartphone 30 5 2 Connection to a personal computer 30 5 3 How to install the USB driver 31 5 4 How to us...

Страница 4: ...n either personal injury or property damage Don t indicates a prohibited action that you must NOT do Do indicates a mandatory action that you must do Before using the DF870 carefully read and understand the following instructions labeled as Danger Warning and Caution and ensure to observe them Danger Never use the DF870 together with the following medical electronic devices Otherwise these devices...

Страница 5: ...any places other than on the platform Otherwise the DF870 may tip over leading to serious injuries If you have any physical impairment ask a helper for assistance Do not jump or bounce on the DF870 You may trip or fall and suffer serious injuries It may also cause machine failure Gently step on the platform Do not forcibly bend the power plug or place anything heavy on it Otherwise the power plug ...

Страница 6: ...h the thermal head section immediately after printing The section can be very hot immediately after printing You may burn yourself if you touch it Do not drop the DF870 Do not place it on its side during storage Otherwise machine failure may occur To prevent damage to the DF870 1 Do not push the display panel or operation keys with your fingernail or other pointed objects 2 Observe the specified i...

Страница 7: ...ive impact or vibration or near any devices that emit strong electromagnetic waves e g microwave ovens 3 Use the DF870 on a level stable place which is rigid enough to sustain the load 4 Use the DF870 in the specified operating conditions 5 C 35 C 30 85 RH Note that even in the specified operating range measured results may become inaccurate under the following conditions where condensations occur...

Страница 8: ...function To subtract the weight of the clothes in advance If you press numeric keys when zero weight is indicated on the LCD the Tare setting screen appears where you can set the weight of the clothes in advance to subtract the weight Transactions or certifications To write a measured weight in the patient chart If you are using the DF870 designed for transactions or certifications you can write t...

Страница 9: ...th a solution of up to 80 alcohol concentration 2 wipe stains off the DF870 with the cloth 3 wash the DF870 with clean water and then 4 carefully wipe off the moisture with a clean dry cloth Wash the display panel with clean water Never disassemble or modify the DF870 Otherwise it may deteriorate the water proof performance of the DF870 If by any chance you have disassembled the DF870 by mistake b...

Страница 10: ...Chapter 1 Read these instructions before use 9 ...

Страница 11: ...mn and attach the back plate with the knurled head screws As shown in the figure below ensure to attach the back plate with the power cable drawn out of the slit If you wish to connect a ground wire connect it to a screw on the back of the column Press the printer open close key to open the paper cover and set printing paper upward as shown in the figure below Set the paper so that its end is prot...

Страница 12: ...clockwise to lower the DF870 and turn them counterclockwise to raise the DF870 2 3 Display panel and operation keys Display panel Operation keys Power key Press this key to turn on the power Press and hold this key to shut down the power Indication hold key Fixes the indicated body weight until the person steps down from the DF870 Mode key Switches between Weight mode and Body Composition mode Zer...

Страница 13: ... Mode key Set key Press and then press Body Composition mode You can measure a person s body fat percentage and muscle mass in addition to his her weight Weight mode You can measure a person s weight which can be entered in his her patient chart can be entered only when using the DF870 designed for transactions or certifications Body Planner To reset the value to 0 00kg Zero reset Zero reset key P...

Страница 14: ... put on the DF870 from measured weight One touch tare in Weight mode only Tare key Place a tare on the DF870 and press Net sign comes on with a short beep sound Then the panel shows 0 00kg to subtract the weight of the item placed on the DF870 To clear the tare press Tare key again while nothing is placed on the platform When the tare is cleared the panel shows 0 00kg Body Planner To hold the indi...

Страница 15: ...Chapter 2 Preparations before use 14 ...

Страница 16: ...the DF870 and press When the measured value is stable the DF870 prints the weight and tare Body Planner To print the weight value automatically in Weight mode only Select Weight mode and set the Indication hold After the indication is held the DF870 prints the weight and tare Body Planner To turn off the power Power key Press and hold The screen goes out in a few seconds ...

Страница 17: ...ing the following optimal time period for measurement wherever possible Body Planner Optimal time for measurement 10 a m to 12 noon Take off your socks when you measure Wipe your finger tips and the soles of your feet with a wet towel Body Planner You cannot get the correct measurement results in the following cases Wait for about two hours before measurement Just after waking up Just after eating...

Страница 18: ...our socks and stockings Wipe your finger tips and the soles of your feet with a wet towel To change the mode see page 12 Input the tare for clothes Example If the clothes weigh 1 25kg Press the numeric keys 1 2 5 Tare key Then press Measure your weight Input your height Example If you are 174 0cm tall Set key Press 1 7 4 0 Then press Return key Press to input your height again ...

Страница 19: ...o not know your waist size press 0 Input your age Example If you are 25 years old Set key Press 2 5 Then press Input your sex Set key If you are a male press 1 Then press Set key If you are a female press 2 Then press Check the information you have input Set key If the information is correct press Return key To make the settings again press ...

Страница 20: ...he stick Attention Ensure that the stick is facing the correct side Front Put your fingers on the finger electrodes and hold the stick Put your index and middle fingers on the upper electrodes put your thumbs on the lower electrodes and hold the stick Straighten your back and stretch your arms forward Straighten your back and stretch your arms straight forward at the level of your shoulders Finger...

Страница 21: ... judgment of your body Standard type Your BMI body fat percentage and visceral fat index are all in the standard range Hidden obese type Your body fat percentage exceeds the standard range Obese type Your BMI or visceral fat index exceeds the standard range Set key When you have confirmed it press to proceed Confirm the evaluation of your weight Set key When you have confirmed it press to proceed ...

Страница 22: ...evaluation of your body composition for each limb Set key When you have confirmed it press to proceed Confirm the QR code The measurement is now complete Tear off the printed paper and get off the scale Reprint the measured results how to print another sheet Mode key Press while the measured results are shown on the screen Set key Press to reprint the results ...

Страница 23: ...is a muscle which is connected to a bone and moves the body You can increase the mass through exercise People with large amounts of skeletal muscle consume more energy and do not put on weight easily Lean mass This is determined by subtracting the fat mass from the total body weight and includes skeletal muscles in addition to heart muscles and water content The Limb value is determined by subtrac...

Страница 24: ...Obesity Diseases Second Edition by the Japan Society for the Study of Obesity with some additions No 4 Criteria for the fat percentage for each body part Evaluation Under Normal Slightly over Over Printed as Under Normal Obese Arms Male 14 9 or less 15 0 to 19 9 20 0 to 24 9 25 0 or over Female 31 9 or less 32 0 to 38 9 39 0 to 45 9 46 0 or over Legs Male 14 9 or less 15 0 to 18 9 19 0 to 22 9 23 ...

Страница 25: ...e body Male 22 0kg 24 0kg Female 14 0kg 17 0kg Arms Male 1 5kg 1 6kg Female 0 9kg 1 1kg Legs Male 5 5kg 5 8kg Female 3 5kg 4 0kg From research by Yamato Scale No 9 Average values of estimated bone mass Weight 69 9kg or less Weight 70 0kg or over Male 2 4kg 2 8kg Weight 50 0kg or less Weight 50 0 to 60 0kg Weight 60 0kg or over Female 1 9kg 2 1kg 2 3kg From research by Yamato Scale 3 5 How to set t...

Страница 26: ...base method Then you can monitor your condition with more accurate results Furthermore the Personal correction function also allows you to obtain results that are consistent with a body composition monitor you have used in the past Input the difference in the same way and you can monitor the conditions consistently Input values for personal correction CT visceral fat area cm2 DF870 s visceral fat ...

Страница 27: ...tings as needed Zero reset key Tare key Press and at the same time 1 Time setting Set the date and time 2 Operation setting Set the operating conditions for each category 3 Parameter list Set the operating conditions from a list 4 Number of meas Confirm the number of past measurements 4 2 Time setting User menu 1 Time setting allows you to set the date and time 24 hour format Press 1 to set the da...

Страница 28: ... composition monitor press 1 To make the Printing settings press 2 To make the Communication settings press 3 To make the Scale settings press 4 Use a numeric key to select an item Zero reset key Tare key Use or to select an option Set key and press Parameter list User menu 3 Parameter list displays a list of parameters Zero reset key Tare key Use or to select an item and make the setting ...

Страница 29: ... Paper feed after printing Set the amount of feeding the paper after the completion of printing Operation setting Communication setting Communication Set whether or not to communicate with a personal computer and if you do set the communication means via the USB port or Bluetooth option Comm speed USB COM Set the speed of sending data to a personal computer via the USB port Operation setting Scale...

Страница 30: ... 38400bps 6 57600bps 7 115200bps 020 Measurement mode during ON 0 Weight mode 1 Body Composition mode 2 From previous state 023 Display time of meas wt 0 0 sec 1 1 sec 2 2 sec 3 3 sec 4 4 sec 5 5 sec 6 6 sec 7 Key input 027 Judgment of body 0 None 1 Set 028 Paper feed after printing 0 None 1 15 Feed the specified number of lines 030 Personal correction 0 None 1 Set 4 5 Number of measurements You c...

Страница 31: ... App icon Major screens of the smartphone application Detailed information screen of measured results Detailed information screen of measured results Screen for measured results of each body part QR code scanning screen 5 2 Connection to a personal computer You can import measured results of the DF870 into a personal computer by downloading the dedicated application DF870 communication software To...

Страница 32: ... Support 20Documents Software CP210x_Windows_Drivers zip Open the file When the download is complete Internet Explorer starts up Click Open the file O Extract the installer When you click Open the file O the following installers exe appear For 32bit PCs double click CP210xVCP installer_x86 exe For 64bit PCs double click CP210xVCPinstaller_x64 exe To confirm whether your PC is a 32bit or 64bit syst...

Страница 33: ...ed under Ports COM LPT the driver is normally installed Write down the assigned COM number on a memo and remember it because you need to use it in an upcoming setup step 5 4 How to use the DF870 communication software On our website select Product Health care etc and enter the page for the DF870 Download DF870 communication software from the page When you extract the downloaded file the following ...

Страница 34: ...o the DF870 While DF870 communication software is opened input data in Row 1 i e a sex male 1 female 0 in Column A an age in Column B a height in Column C a waist size in Column D and the tare for clothes in Column E Then Save and close the file When you measure a weight in Body Composition mode of the DF870 at this point the system sends the input values to the DF870 to immediately start measurem...

Страница 35: ...on setting again 3 If there is anything unclear please contact us For the explanation of gravity acceleration for each region refer to the website of the Geospatial Information Authority of Japan http www gsi go jp Region Prefecture Range of gravity acceleration m s2 Setting value Hokkaido Hokkaido 9 803 9 807 120 Tohoku north Aomori Iwate Akita Miyagi Yamagata 9 799 9 804 113 Fukushima Niigata No...

Страница 36: ...Chapter 6 DF870 for other than transactions or certifications 35 Okinawa area including a part of Kagoshima Prefecture Kagoshima excluding Satsuma and Osumi areas Okinawa 9 789 9 794 93 ...

Страница 37: ...alue Setting value Gravity acceleration m s 9 7600 10000 5 30 offset Refer to Gravity acceleration setting for each region on page 34 Zero reset key Tare key Press and at the same time User menu Call the User menu 3 Parameter list Set key Select 009 Gravity acceleration and press Input the setting value with numeric keys Set key Then press ...

Страница 38: ...ce or factory 15 25 m If a cabinet is placed in between About 10 m Factors affecting the communication range Bluetooth wireless communication uses 2 4GHz band which has the properties of high directivity meaning that the signals are difficult to bend around obstacles Therefore if you block a communication path by placing a cabinet or other object the communication distance may become extremely sho...

Страница 39: ...t Bluetooth The PC scans nearby Bluetooth devices Click Pair button If the PC detects a Bluetooth device installed in the DF870 the device name appears on the screen Click Pair button to connect The device name is the same as the code indicated on the sticker attached to the connector port of the finger electrodes If the indication switches to Connected the connection is complete Confirm the COM p...

Страница 40: ...If you wish to use the DF870 on a PC that is not paired you need to unpair the paired PC first This procedure is not used for normal operations Do it only if necessary Zero reset key Tare key Press and at the same time User menu Call the User menu 2 Operation setting and select 3 Communication setting Then select 3 Bluetooth Unpairing Set key Press and hold to unpair the device If you cannot unpai...

Страница 41: ...f mass Use the DF870 within the weighing capacity Initial error Indicates that the power is turned on when an item exceeding the zero point reset limit is placed Check that nothing is placed on the platform and then turn on the power Initial error Indicates that the power is turned on with the platform slightly risen Check that nothing is in contact with the platform and then turn on the power Zer...

Страница 42: ...arameters Set the user parameter 006 to 1 and set the 011 to 1 or 2 Connection error Printer error The communication is not established The printer may have failed Check the setting of the serial port Check the settings of Bluetooth Bluetooth error A failure may have occurred Consult your vendor Printer error Orange lamp comes on Roll paper is not set in the printer or the printer cover is open Se...

Страница 43: ...DFI 870 1 Display tube Dot matrix display tube 2 Font size 9 W mm 26 H mm 3 Indications Mass indication Up to 5 digits Stable sign Comes on when the measured value is stable Zero sign Comes on when the zero point reset is enabled Net sign Comes on when the tare subtraction is enabled Hold sign Comes on when the indication hold function is enabled Hold on sign Comes on when the indication hold is i...

Страница 44: ... 11 Power supply 1 Power 100V AC 10 to 15 50 60Hz 2 Power consumption Max 20W 12 Operating conditions 1 Temperature range 5 C 35 C 2 Humidity range 30 85 R H no condensation 13 Applicable laws and standards Measurement Act Japan JIS B7611 2 2015 Level L for certification 14 Option Bluetooth wireless communication 15 Printing system Thermal line dot type 1 Printing paper size Width 58mm x φ50 Max L...

Страница 45: ...eletal muscle ratio 20 0 50 0 Unit 0 1 Skeletal muscle ratio of right arm 20 0 60 0 Unit 0 1 Skeletal muscle ratio of left arm 20 0 60 0 Unit 0 1 Skeletal muscle ratio of right leg 20 0 70 0 Unit 0 1 Skeletal muscle ratio of left leg 20 0 70 0 Unit 0 1 Visceral fat index 5 300 Unit 5 Basal metabolic rate 200 4800kcal Unit 1 kcal Basal metabolism standard 200 4800kcal Unit 1 kcal Estimated bone mas...

Страница 46: ...Chapter 9 Specifications 45 9 1 Outside drawing ...

Страница 47: ...YAMATO SCALE CO LTD 5 22 Saenba cho Akashi 673 8688 Japan Telephone 81 78 918 6157 Telefax 81 78 918 5562 Revised edition 1 January 28 2020 ...