CHAPTER 5 Installation
5-16
Much mechanical friction?
Are wiring and connector
securely connected?
Is wiring live?
Is motor resistance OK?
Is motor encoder OK?
Is controller hardware OK?
Turn power off and check for friction
by moving manually
Is brake installed?
Securely connect wiring and connector
Replace motor since motor has shorted or burnt out
Is there electrical
discontinuity?
Repair
Are connector pins
securely inserted?
Securely insert pins or repair defective pins
When feedback error is occurring, perform
continuity check
(1) Check motor power supply lines U, V and W
(2) Check encoder signal lines for phases A and B
(1) Check position shift by repetitive accuracy measurement
(2) If replacement motor is available, check by exchanging the motors
Replace motor
Is external noise large?
Take noise reduction measures
Yes
No
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Feedback error
Any foreign matter
caught inside?
Adjust mechanical alignment
No
No
Is 24V supplied to brake?
Replace power supply unit or repair defective parts
No
Yes
Yes
Repair
Yes
Is there electrical
discontinuity?
Is brake sound
heard when turning power
on and off?
Recheck
No
Are parameters
for controller and
robot OK?
Initialize parameters
No
(1) If replacement controller is available, check by
exchanging the controllers
Replace motor (with brake)
Yes
Содержание YP-X Series
Страница 1: ...OWNER S MANUAL ...
Страница 2: ......
Страница 6: ...MEMO ...
Страница 10: ...MEMO ...
Страница 12: ...MEMO ...
Страница 29: ...CHAPTER 2 Functions 1 P P robot unit 2 1 2 P P robot controller 2 2 ...
Страница 30: ...MEMO ...
Страница 34: ...MEMO ...
Страница 42: ...CHAPTER 3 Installation 3 8 Robot Cable DRCX YP320X Fig 3 5 Robot cable connections ...
Страница 46: ...MEMO ...
Страница 56: ...4 10 MEMO ...
Страница 58: ...MEMO ...
Страница 82: ...MEMO ...
Страница 109: ...MEMO ...