CHAPTER 3 Installation
3-5
(2) YP330X, YP340X installation
Eight M8 screw holes (pitch 1.25 mm) are provided in the base section of the
YP330X and YP340X units. Use four of these holes for the installation.
!
CAUTION
The plate thickness of the base is 20 mm so make sure the bolts do not
exceed this distance and protrude into the robot interior.
1) Drill holes (approx. 10 dia.) into the frame installation surface as shown.
2) Tighten with a hex head bolts from the rear side of the frame through the
holes.
The M8 bolt tightening torque is 230 to 370 kgcm.
YAMAHA YP SERIES
Depth 20
12
60
175
60
8-M8
×
1.25
319
12.5
255
280
Fig. 3-2 YP330X, YP340X installation
WARNING
Be sure to use the specified type and number of bolts, and securely
tighten them to the correct torque. If the bolts are not tightened
correctly, the robot may cause positioning errors or fall over during
operation, causing a serious accident.