CHK
ADJ
3-46
CHECKING AND CHARGING THE BATTERY
Charging method using a variable-current (voltage) charger
Measure the open-circuit
voltage prior to charging.
Connect a charger and
ammeter to the battery and
start charging.
Is the amperage higher than
the standard charging
amperage written on the
battery?
Adjust the voltage to obtain the
standard charging amperage.
Set the timer to the charging
time determined by the open-
circuit voltage.
Refer to “CHECKING AND
CHARGING THE BATTERY”
Adjust the charging voltage to
20 ~ 25 V
Monitor the amperage for 3 ~ 5
minutes. Is the standard
charging amperage exceeded?
If the amperage does not
exceed the standard charging
amperage after 5 minutes,
replace the battery.
If the required charging time exceeds 5 hours, it is advisable to check
the charging amperage after 5 hours. If there is any change in the
amperage, readjust the voltage to obtain the standard charging
amperage.
Leave the battery unused for more than 30 minutes before measuring
its open-circuit voltage.
12.8 V
→
Charging is complete.
12.0 ~ 12.7 V
→
Recharging is required.
Under 12.0 V
→
Replace the battery.
YES
YES
NO
NO
Set the charging voltage to
16 ~ 17 V. (If the charging
voltage is lower, charging
will be insufficient, if it is
higher, the battery will be
over-charged.
NOTE:
Leave the battery unused
for more than 30 minutes
before measuring its open-
circuit voltage.
NOTE:
Charge