3 - 25
INSP
ADJ
BATTERY INSPECTION AND CHARGING (TT-R90E)
NOTE:
Since MF batteries are sealed, it is not possi-
ble to check the charge state of the battery by
measuring the specific gravity of the electro-
lyte. Therefore, the charge of the battery has to
be checked by measuring the voltage at the
battery terminals.
1. Remove:
• Seat
• Rear fender
2. Disconnect:
• Battery lead coupler
1
(from the battery terminals)
NOTE:
Push down on the tab
a
, and then remove the
battery lead coupler.
3. Remove:
• Battery
1
a
4. Measure:
• Battery charge
Measurement steps:
• Connect a pocket tester
1
to the battery
terminals.
Tester positive probe
→
battery positive
terminal
Tester negative probe
→
battery negative
terminal
NOTE:
• The charge state of an MF battery can be
checked by measuring its open-circuit volt-
age (i.e., the voltage when the positive ter-
minal is disconnected).
• No charging is necessary when the open-
circuit voltage equals or exceeds 12.8 V.