TIONS
[PLC data assignment]
X0 (*1)
: Unit error
X1 (*1)
: Local station data link status
X6 (*1)
: Data link start normal completion
X7 (*1)
: Data link start error completion
X0F (*1)
: Unit ready
X100
: 1st unit’s SO(00): Emergency stop input status
X101
: 1st unit’s SO(01): CPU_OK
:
:
X17F
: 1st unit reservation
X180
: 2nd unit’s SO(00): Emergency stop input status
X181
: 2nd unit’s SO(01): CPU_OK
:
:
X1FF
: 2nd unit reservation
Y0 (*1)
: Refresh instruction
Y6 (*1)
: Data link start request
Y100
: 1st unit’s SI(00): Emergency stop input
Y101
: 1st unit’s SI(01): Servo ON input
:
:
Y17F
: 1st unit reservation
Y180
: 2nd unit’s SI(00): Emergency stop input
Y181
: 2nd unit’s SI(01): Servo ON input
:
:
Y1FF
: 2nd unit reservation
M0
: Unit preparation complete flag
M1
: Parameter setting flag
M2
: Data link start flag
M4
: 1st station data link status
M8
: 5th station data link status
D0
: No. of connection units storage device
D1
: 1st unit local station information setting storage device
D2
: 2nd unit local station information setting storage device
D10
: Parameter setting status storage device
*1: This number is determined by the master module mounting position and the number
of occupied input/output points mounted before the module.
4. Sample program
Содержание RCX series
Страница 1: ...User s Manual ENGLISH E E78 Ver 1 08 CC Link YAMAHA NETWORK BOARD RCX series ...
Страница 2: ......
Страница 12: ......
Страница 22: ......
Страница 34: ...2 12 MEMO ...
Страница 36: ......
Страница 50: ......
Страница 60: ......
Страница 81: ...Chapter 6 APPENDIX Contents 1 Term definition 6 1 ...
Страница 82: ......