8-24
–
+
ELEC
E
ELECTRICAL ANALYSIS
M57300-0
THERMO SWITCH
1. Immerse the thermo switch in water.
While heating the water, check the con-
tinuity at the specified temperature.
2. While cooling the water, check the con-
tinuity at the specified temperature.
If continuity is not as specified, replace
the thermo switch.
1
Discontinuity
2
Continuity
3
Discontinuity
Å
Temperature
ı
Time
ON temperature
a
:
84 ~ 90˚C (183 ~ 194˚F)
OFF temperature
b
:
60 ~ 74˚C (140 ~ 165˚F)
FUEL ENRICHMENT VALVE
1. Measure the resistance of the fuel
enrichment valve.
NOTE:
Refer to “Low resistance measurement” for
this inspection.
Fuel enrichment valve resistance:
at 20˚C (68˚F)
L – B: 3.4 ~ 4.0
Ω