7-29
E
BRKT
POWER TRIM AND TILT UNIT
3. Connect the leads to a battery to check
the fluid discharge pressure during
down-operation.
CAUTION:
The motor should not be operated for more
than three seconds after trim and tilt down
is completed.
A: Tilt operating pressure
B: Trim operating pressure
4. Connect the leads to a battery to check
the fluid discharge pressure during up-
operation.
NOTE:
The motor should not be operated for more
than fourteen seconds after full tilt up-oper-
ation.
Trim and tilt down ........ Green (+)
Blue (–)
At the end of down operation:
[Stamped mark]
[6H308]
A: 4,100 ~ 5,500 kPa
(41 ~ 55 kg/cm
2
, 583 ~ 782 psi)
B: 600 ~ 1,100 kPa
(6 ~ 11 kg/cm
2
, 85 ~ 157 psi)
[6H1-15]
A: 2,200 ~ 3,800 kPa
(22 ~ 38 kg/cm
2
, 313 ~ 540 psi)
B: 600 ~ 1,100 kPa
(6 ~ 11 kg/cm
2
, 85 ~ 157 psi)
[62F-02]
A: 2,100 ~ 3,700 kPa
(21 ~ 37 kg/cm
2
, 299 ~ 526 psi)
B: 600 ~ 1,100 kPa
(6 ~ 11 kg/cm
2
, 85 ~ 157 psi)
Trim and tilt up.............. Blue (+)
Green (–)