8-21
–
+
ELEC
E
ELECTRICAL ANALYSIS
M55000-0
STARTER RELAY
1. Check for continuity between the termi-
nals and the ends of the black and
brown leads.
2. Test to ensure there is no continuity
between terminals.
3. Check the relay operation.
1)
Connect a tester between the termi-
nals of the starter relay. Connect the
leads of the starter-relay to a 12-V
battery.
B
: Black
Br
: Brown
4. Check that there is continuity between
the starter relay terminals. If the opera-
tion is not as specified, replace the
starter relay.
Brown lead........................................ (+)
Black lead .......................................... (–)
Battery voltage:
12V
M51410-0
POWER TRIM AND TILT RELAY
1. Check the relay for terminal looseness
and for wiring rust and corrosion.
Replace the relay if any of the three
defects is found.
2. Connect the (+) terminal and
1
terminal
and the (+) terminal and
2
terminal to
the tester and check that the resistance
becomes
∞
in each case.