6-31
E
LOWR
INSTALLATION
165000-0
LOWER UNIT LEAKAGE CHECK
1. Tighten the gear oil-drain screw and
connect the tester to the oil-level hole.
2. Pump the tester, and apply a pressure
of 100 kPa (1.0 kg/cm
2
, 14.2 psi).
Then, place the gear case in the water
tank.
3. Check that the pressure is held at
100 kPa (1.0 kg/cm
2
, 14.2 psi) for 10 sec-
onds.
CAUTION:
Do not overpressurize.
NOTE:
If the pressure falls, leakage from the lower
unit is unacceptable, requiring re-inspection
of its component parts.
Å
For USA and Canada
ı
Except for USA and Canada
Pressure tester:
YB-35956/90890-06762
Å
ı