background image

 

Содержание SH-110A5

Страница 1: ...OIL PUMP SH 110A5 ITEM No 851753 DR 110A5 ITEM No 851754 PD 110A5 ITEM No 851755 WARNING Prior to operating this pump be sure to read this operation manual for safety After reading the manual please...

Страница 2: ......

Страница 3: ......

Страница 4: ...by symbols These symbols are for those who will operate this product and for those who will be nearby for safe operation and for prevention of personal injury and property damage The following warnin...

Страница 5: ...tion Attach a valve for stop in emergency or regulator to the air supply pipe to keep supply air pressure under 0 7 MPa Discontinue it when you feel a hazard or abnormality during the work And corresp...

Страница 6: ...alling the pump Back injury may be caused by lifting the pump Do not touch the surfaces of the pump and the hose when pumping high temperature material Risk of burns exists Stop the air supply source...

Страница 7: ...he Drum Pump 2 3 2 Installing the Siphon Pump 3 3 3 Installing the Draw Change Material Hose 3 3 4 Installing the Pressure Feed Material Hose 3 3 5 Air Connection 4 3 6 Connecting the ground wire 4 4...

Страница 8: ...acked in a corrugated fiberboard case Please make sure no damage during shipment and no missing accessories after unpacking as soon as possible Please make sure no loose screws piping connections and...

Страница 9: ...ling tapes to the male screws and tighten tightly when the pipes are connected Be careful not to allow the sealing materials to enter the piping Do not apply the tip of the terminal two thread ridges...

Страница 10: ...rew of the bang adapter to fix the suction hose assembly Fig 2 3 3 Installing the Draw Change Material Hose 1 Install the material hose separately available at the material discharge port Rc3 4 of the...

Страница 11: ...hose the pump is in operation Before connecting the air hose be sure to turn the knob of the air regulator counterclockwise to reset the pointer of the pressure gauge to 0 Using the air regulator perm...

Страница 12: ...replace the drum can with a new one For replacing the drum can observe the item pertaining to 3 1 Installing the Drum Pump The distance for pressure feed differs depending on the viscosity temperature...

Страница 13: ...oil does not leak at the exhaust port Check if there is any open valve on the material output side The air motor is faulty Ask for servicing the air motor When the outlet side is closed check if any l...

Страница 14: ...regulator 2 Inject a few drops of lubricating oil approx 0 5 mL into the air supply port as shown in the figure at right Use turbine oil class 1 ISO VG 32 or equivalent as the lubricating oil 5 3 Cons...

Страница 15: ...od of A weighted sound power level is based on ISO 3744 3 Discharge volume per cycle varies according to use conditions MAXIMUM OPERATING NOISE 5 x 1 TYPE ITEM No PUMP RATIO NOMINAL FLUID CONNECTION O...

Страница 16: ...753 SH 110A5 type Panel Unit 850126 Suction Hose Assembly No Parts No Descriptions Q ty 1 801102 Delivery hose assembly 1 2 805062 Panel option 1 3 802558 Air regulator assembly 1 4 800400 Mounting br...

Страница 17: ...cause corrosion inflation or dissolution of the component parts of the product 4 Irregularity arising from repair made by other than by our firm our regional office dealer or authorized service perso...

Страница 18: ...MEMO...

Страница 19: ......

Страница 20: ...FAX 31 0 74 242 1055 E mail sales yamada nl Web www yamada europe com Manufactured by YAMADA CORPORATION INTERNATIONAL DEPARTMENT 1 1 3 Minami Magome Ota ku Tokyo 143 8504 Japan PHONE 81 0 3 3777 0241...

Отзывы: