Changing Mode Setting (Accusense 20A)
NOTE:
Mode settings can be checked by connecting
the battery charger to a 120V AC power source and
watching the LED display. The LED display will flash
once if the mode is set to Mode 1, twice if set to Mode
2, three times if set to Mode 3, and so forth. If the
LEDs do not flash when initially connected to power,
refer to Troubleshooting (Accusense 20A Chargers) in
this section.
For lift trucks manufactured before May, 2013, modes
are set by the position of the jumpers on the jumper
port (behind mode key). Accessing the jumper port re-
quires removal of a plate on the front of the battery
charger on Accusense 20A chargers.
1.
Remove the screws used to retain the jumper port
cover to the charger and remove the cover.
2.
Locate the jumpers on the port.
3.
Arrange the jumpers in the proper configuration
for your battery type.
4.
Replace the cover on the charger and install the
mounting screws.
For lift trucks manufactured after May, 2013, modes
are set by the sequence of the dip switches. Contact
Service Engineering for dip switch settings. Tamper-
ing with the Charging Mode Label voids warranty.
Contact Service Engineering to set dip switches.
TROUBLESHOOTING (ACCUSENSE 20A
CHARGERS)
General
NOTE:
The charger runs a pre-qualifying test (yellow
charging light flashing) at the beginning of the charge
cycle to determine the condition of the battery. This
test may last from 45 minutes to five hours. After the
test is complete, the charger should begin charging
(yellow charging light continuous) or may display an
Error Mode by flashing one or more of the red LEDs.
If an Error Mode is displayed, stop the general trou-
bleshooting and follow the chart and procedures in Er-
ror Modes in this section.
1.
Check AC power supply to charger:
a.
Connect the charger plug to a 120 volt AC
power source using a 20 amp rated extension
cord.
b.
Do all 5 LEDs simultaneously flash at least
once upon connection? (LEDs should flash be-
tween one to four times depending on battery
type/mode configuration.)
(1) YES:
(2) NO:
Check AC power supply to charger:
Inspect all cabling for proper connections
(check for loose or corroded connectors) or
broken wires. Repair as necessary and re-
peat Step 1. If LEDs still do not flash at
least once upon connecting power, replace
the charger.
2.
Check that the charger is configured for the
proper battery mode/type:
a.
What is the proper charger mode for the type
batteries being used?
(1)
Refer to Charger Mode/Battery Type Se-
lection (Accusense 20A).
b.
What mode is the charger currently set on?
(1)
Connect the charger plug to a 120 volt AC
power source using a 20 amp rated exten-
sion cord.
(2)
How many times do all 5 LEDs flash upon
connection?
c.
Is the charger currently set to the proper mode
for the battery type being used?
(1) YES:
(2) NO:
Change the charger mode to the
proper setting for the battery type being
used. See or Changing Mode Setting (Ac-
cusense 20A). After changing the mode
setting repeat Step b to verify the proper
mode has been selected.
NOTE:
The charger runs a pre-qualifying test (yellow
charging light flashing) at the beginning of the charge
cycle to determine the condition of the battery. This
test may last from 45 minutes to five hours. After the
test is complete, the charger should begin charging
(yellow charging light continuous) or may display an
Error Mode by flashing one or more of the red LEDs.
If an Error Mode is displayed, stop the general trou-
bleshooting and follow the chart and procedures in Er-
ror Modes in this section.
Battery Charger (Accusense
®
20A)
2200 YRM 1007
50
Содержание MPB040-E
Страница 4: ......
Страница 10: ...Hydraulic Pump 1900 YRM 1018 Figure 4 Hydraulic Unit 6 ...
Страница 19: ......
Страница 65: ...Figure 30 Switch Position Mode Chart 2200 YRM 1007 Battery Charger Accusense by DPI 41 ...
Страница 79: ......
Страница 80: ...2200 YRM 1007 10 16 8 16 1 14 9 13 12 12 7 11 ...
Страница 81: ...Maintenance LIFTING MECHANISM MPB040E B827 MPW045 E B802 MPW050 E C802 PART NO 524154897 4000 YRM 1008 ...
Страница 84: ......
Страница 93: ......
Страница 95: ...Maintenance DC MOTOR MAINTENANCE ALL ELECTRIC LIFT TRUCKS PART NO 524158039 0620 YRM 0294 ...
Страница 98: ......
Страница 128: ...NOTES 30 ...
Страница 129: ......
Страница 130: ...0620 YRM 0294 9 16 3 08 6 15 3 06 8 03 ...