![Yale MPB040-E Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/yale/mpb040-e/mpb040-e_manual_3124464039.webp)
Fuses
WARNING
Before checking or changing any fuses, make cer-
tain the battery has been disconnected.
Always wear safety glasses. Block the tires, remove
the key from the key switch, disconnect battery, and
discharge the capacitors before making checks or re-
pairs in the drive unit compartment. See Special Pre-
cautions.
MPB040-E
The MPB040-E 24-volt motorized hand trucks have
two fuses. They are:
1.
175-amp (FU 1) protects both the lift pump mo-
tor and the drive motor
2.
5-amp (FU 2) protects the control circuits
MPW045/050-E
The MPW045-E and MPW050-E 24-volt lift trucks
have two fuses. They are:
1.
250-amp (FU 1) protects both the lift pump mo-
tor and the drive motor.
2.
5-amp (FU 2) protects the control circuits.
The MPW045-E and MPW050-E 12-volt lift trucks
have three fuses. They are:
1.
250-amp (FU 1) protects both the lift pump mo-
tor and the drive motor.
2.
5-amp (FU 2) protects the control circuits.
3.
5-amp (FU 3) protects the 12-volt DC to 24-volt
DC converter circuit.
MSW020/025-E
The MSW020/025-E 24-volt lift trucks have two fuses.
They are:
1.
250-amp (FU 1) protects both the lift pump mo-
tor and the drive motor.
2.
5-amp (FU 2) protects the control circuits.
If it cannot be determined visually that any of the
fuses have failed, check for continuity using an ohm-
meter. To replace FU 1, loosen retaining capscrews.
Install a new fuse and tighten capscrews. FU 2 is re-
tained by a fuse holder. Make certain that any re-
placement fuse is of the right amperage before instal-
lation.
MSW025/030-F
The MSW025/030-F 24-volt lift trucks have three
fuses. They are:
1.
FU 1 protects both the lift pump motor and the
drive motor.
2.
FU 2 protects the control circuits.
3.
FU 3 protects the control circuits.
If it cannot be determined visually that any of the
fuses have failed, check for continuity using an ohm-
meter. To replace FU 1, loosen retaining capscrews.
Install a new fuse and tighten capscrews. FU 2 or FU
3 are retained by a fuse holder. Make certain that any
replacement fuse is of the right amperage before in-
stallation.
2200 YRM 1007
Fuses
15
Содержание MPB040-E
Страница 4: ......
Страница 10: ...Hydraulic Pump 1900 YRM 1018 Figure 4 Hydraulic Unit 6 ...
Страница 19: ......
Страница 65: ...Figure 30 Switch Position Mode Chart 2200 YRM 1007 Battery Charger Accusense by DPI 41 ...
Страница 79: ......
Страница 80: ...2200 YRM 1007 10 16 8 16 1 14 9 13 12 12 7 11 ...
Страница 81: ...Maintenance LIFTING MECHANISM MPB040E B827 MPW045 E B802 MPW050 E C802 PART NO 524154897 4000 YRM 1008 ...
Страница 84: ......
Страница 93: ......
Страница 95: ...Maintenance DC MOTOR MAINTENANCE ALL ELECTRIC LIFT TRUCKS PART NO 524158039 0620 YRM 0294 ...
Страница 98: ......
Страница 128: ...NOTES 30 ...
Страница 129: ......
Страница 130: ...0620 YRM 0294 9 16 3 08 6 15 3 06 8 03 ...