![Yale MPB040-E Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/yale/mpb040-e/mpb040-e_manual_3124464057.webp)
•
If the AC input fuse is blown, replace and re-
connect the charger to the AC outlet. Check
AC voltage while in operation to confirm the AC
wall circuit is still within the acceptable range,
108 to 126 volts. If the AC wall circuit is still
within the acceptable limits, return the charger
to service. If it is not,
DO NOT
return the
charger to service until a building circuit with
acceptable output can be found.
If the charger will power up, but does not charge, pro-
ceed with the following:
•
Check condition of battery connections and
clean them, if necessary.
•
Verify that the batteries are properly connec-
ted. See
Diagrams
8000YRM1011,
Diagrams
8000YRM1050,
Diagrams
8000YRM1381, or
Diagrams
8000YRM1228 for your lift truck.
Identify and replace any batteries with open or
shorted cells.
•
Check battery output voltage to verify charge is
actually necessary. Charger may not run if bat-
teries are already sufficiently charged.
•
If battery output voltage indicates need for
charging and the unit will not charge, check the
internal 50 amp DC output fuse and replace if
necessary. First remove the four Phillips head
screws on the side of the charger and slide the
cover off to access the fuse. See Figure 24.
•
If the DC output fuse requires replacement, this
could be an indication of an improperly wired
battery pack. Verify that all battery connections
are correct and remove all debris and metal
fragments from the blown fuse before putting
charger back in service.
•
If the DC output fuse is good, verify that both
retaining nuts are adequately tightened. Exer-
cise caution not to over tighten the nuts, which
could result in board damage.
NOTE:
If the 50 amp DC output fuse has blown,
some debris can be expected on the circuit board
next to the fuse. However, care should be taken to re-
move the debris before putting the unit back in serv-
ice. See Figure 25.
•
Visually inspect for signs of heat damage on
the circuit board and or transformer. If any heat
damage is evident, reassemble and replace
the charger.
1.
INPUT FUSE
Figure 23. Input Fuse Location
2200 YRM 1007
Battery Charger (Moran
®
)
33
Содержание MPB040-E
Страница 4: ......
Страница 10: ...Hydraulic Pump 1900 YRM 1018 Figure 4 Hydraulic Unit 6 ...
Страница 19: ......
Страница 65: ...Figure 30 Switch Position Mode Chart 2200 YRM 1007 Battery Charger Accusense by DPI 41 ...
Страница 79: ......
Страница 80: ...2200 YRM 1007 10 16 8 16 1 14 9 13 12 12 7 11 ...
Страница 81: ...Maintenance LIFTING MECHANISM MPB040E B827 MPW045 E B802 MPW050 E C802 PART NO 524154897 4000 YRM 1008 ...
Страница 84: ......
Страница 93: ......
Страница 95: ...Maintenance DC MOTOR MAINTENANCE ALL ELECTRIC LIFT TRUCKS PART NO 524158039 0620 YRM 0294 ...
Страница 98: ......
Страница 128: ...NOTES 30 ...