Changing Mode Setting
NOTE:
Mode settings can be checked by connecting
the battery charger to a 120V AC power source and
watching the LED display. The LED display on the
charger will flash to indicate the selected battery
mode. Consult Figure 30 to determine the selected
mode. If the LEDs do not flash when initially connec-
ted to power, refer to Troubleshooting (DPI Chargers)
in this section.
Modes are set by the sequence of the dip switches.
Tampering with the Charging Mode Label voids war-
ranty. See Figure 30 for dip switch settings.
TROUBLESHOOTING (DPI CHARGERS)
General
NOTE:
The charger runs a pre-qualifying test (yellow
charging light flashing) at the beginning of the charge
cycle to determine the condition of the battery. This
test may last from 45 minutes to five hours. After the
test is complete, the charger should begin charging
(yellow charging light continuous) or may display an
Error Mode by flashing one or more of the red LEDs.
If an Error Mode is displayed, stop the general trou-
bleshooting and follow the chart and procedures in Er-
ror Modes in this section.
1.
Check AC power supply to charger:
a.
Connect the charger plug to a 120 volt AC
power source using a 20 amp rated extension
cord.
b.
Do all 5 LEDs simultaneously flash at least
once upon connection? (LEDs should flash be-
tween one to four times depending on battery
type/mode configuration.)
(1) YES:
(2) NO:
Check AC power supply to charger:
Inspect all cabling for proper connections
(check for loose or corroded connectors) or
broken wires. Repair as necessary and re-
peat Step 1. If LEDs still do not flash at
least once upon connecting power, replace
the charger.
2.
Check that the charger is configured for the
proper battery mode/type:
a.
What is the proper charger mode for the type
batteries being used?
(1)
Refer to Charger Mode/Battery Type Se-
lection (DPI Gen II Models) or Charger
Mode/Battery Type Selection (DPI Gen III
Models).
b.
What mode is the charger currently set on?
(1)
Connect the charger plug to a 120 volt AC
power source using a 20 amp rated exten-
sion cord.
(2)
How many times do all 5 LEDs flash upon
connection?
c.
Is the charger currently set to the proper mode
for the battery type being used?
(1) YES:
(2) NO:
Change the charger mode to the
proper setting for the battery type being
used. See Changing Mode Setting (DPI
Gen II Models) or Changing Mode Setting
(DPI Accusense Gen III Models with
Jumper Ports). After changing the mode
setting repeat Step b to verify the proper
mode has been selected.
NOTE:
The charger runs a pre-qualifying test (yellow
charging light flashing) at the beginning of the charge
cycle to determine the condition of the battery. This
test may last from 45 minutes to five hours. After the
test is complete, the charger should begin charging
(yellow charging light continuous) or may display an
Error Mode by flashing one or more of the red LEDs.
If an Error Mode is displayed, stop the general trou-
bleshooting and follow the chart and procedures in Er-
ror Modes in this section.
Battery Charger (Accusense by DPI
®
)
2200 YRM 1007
42
Содержание MPB040-E
Страница 4: ......
Страница 10: ...Hydraulic Pump 1900 YRM 1018 Figure 4 Hydraulic Unit 6 ...
Страница 19: ......
Страница 65: ...Figure 30 Switch Position Mode Chart 2200 YRM 1007 Battery Charger Accusense by DPI 41 ...
Страница 79: ......
Страница 80: ...2200 YRM 1007 10 16 8 16 1 14 9 13 12 12 7 11 ...
Страница 81: ...Maintenance LIFTING MECHANISM MPB040E B827 MPW045 E B802 MPW050 E C802 PART NO 524154897 4000 YRM 1008 ...
Страница 84: ......
Страница 93: ......
Страница 95: ...Maintenance DC MOTOR MAINTENANCE ALL ELECTRIC LIFT TRUCKS PART NO 524158039 0620 YRM 0294 ...
Страница 98: ......
Страница 128: ...NOTES 30 ...
Страница 129: ......
Страница 130: ...0620 YRM 0294 9 16 3 08 6 15 3 06 8 03 ...