Troubleshooting
1900 YRM 1018
PROBLEM
POSSIBLE CAUSE
PROCEDURE OR ACTION
Pump produces noise.
Cavitation caused by collapsed suc-
tion hose or clogged screen.
Drain and clean system.
Faulty oil suction.
Add oil to specified level.
Air suction through loose connections
on suction side.
Tighten all hose connections on suc-
tion side.
Air suction from pump oil seal.
Disassemble pump and replace oil
seals.
Breather clogged.
Clean or replace breather.
Cavitation caused by high oil viscosity.
Change to recommended oil and op-
erate pump in recommended temper-
ature ranges.
Abnormal temperature rise of
hydraulic oil.
Overwork.
Adjust workload to fall within pump’s
operating range.
Improper viscosity or contaminated oil.
Drain and replace oil with recom-
mended oil.
Pump case or drive gear bro-
ken.
Incorrect pressure setting.
Check for excessive resistance in hy-
draulic circuit. Make certain relief pres-
sure is properly adjusted and valve is
working properly.
14
Содержание MPB040-E
Страница 4: ......
Страница 10: ...Hydraulic Pump 1900 YRM 1018 Figure 4 Hydraulic Unit 6 ...
Страница 19: ......
Страница 65: ...Figure 30 Switch Position Mode Chart 2200 YRM 1007 Battery Charger Accusense by DPI 41 ...
Страница 79: ......
Страница 80: ...2200 YRM 1007 10 16 8 16 1 14 9 13 12 12 7 11 ...
Страница 81: ...Maintenance LIFTING MECHANISM MPB040E B827 MPW045 E B802 MPW050 E C802 PART NO 524154897 4000 YRM 1008 ...
Страница 84: ......
Страница 93: ......
Страница 95: ...Maintenance DC MOTOR MAINTENANCE ALL ELECTRIC LIFT TRUCKS PART NO 524158039 0620 YRM 0294 ...
Страница 98: ......
Страница 128: ...NOTES 30 ...
Страница 129: ......
Страница 130: ...0620 YRM 0294 9 16 3 08 6 15 3 06 8 03 ...