PROBLEM
POSSIBLE CAUSE
PROCEDURE OR ACTION
Electrical burns on commutator bars
on opposite sides of the commutator
(see Table 2).
Open armature winding.
Replace armature.
Motor has been stalled.
Use correct operating techniques.
Copper wears rapidly at the edge of
the commutator bars (see Table 2).
Operation in a dirty or abrasive en-
vironment.
Clean commutator more fre-
quently.
Wrong type of brushes for this mo-
tor and operation.
Replace brushes with correct type.
Burning/Overheating
1. Flashover causes burning of
the commutator bar.
2. Open circuit in winding cau-
ses deep burning of adjacent
commutator bars.
3. Overheating causes damage
to varnish insulation (see Ta-
ble 2).
Motor has been too hot. Wrong lift
truck for the application. Motor has
been stalled. Open armature wind-
ing. Open field coil.
Use correct lift truck for the appli-
cation. Use correct operating tech-
niques. Replace armature or resur-
face commutator in a lathe. Re-
place field coil.
Commutator bars are either too high
or too loose, both of which can
cause damage to brushes (see Ta-
ble 2).
Motor has been stalled.
Use correct operating techniques.
Motor has been too hot.
Use correct lift truck for the opera-
tion.
0620 YRM 0294
Troubleshooting
29
Содержание MPB040-E
Страница 4: ......
Страница 10: ...Hydraulic Pump 1900 YRM 1018 Figure 4 Hydraulic Unit 6 ...
Страница 19: ......
Страница 65: ...Figure 30 Switch Position Mode Chart 2200 YRM 1007 Battery Charger Accusense by DPI 41 ...
Страница 79: ......
Страница 80: ...2200 YRM 1007 10 16 8 16 1 14 9 13 12 12 7 11 ...
Страница 81: ...Maintenance LIFTING MECHANISM MPB040E B827 MPW045 E B802 MPW050 E C802 PART NO 524154897 4000 YRM 1008 ...
Страница 84: ......
Страница 93: ......
Страница 95: ...Maintenance DC MOTOR MAINTENANCE ALL ELECTRIC LIFT TRUCKS PART NO 524158039 0620 YRM 0294 ...
Страница 98: ......
Страница 128: ...NOTES 30 ...
Страница 129: ......
Страница 130: ...0620 YRM 0294 9 16 3 08 6 15 3 06 8 03 ...