2
General safety notes
14
07.2020
ba
-o
.2
.6
.0
-us
-3
.2
-ys
|
A1
18
67
50
1 Re
v A
E
2.7
Working above floor level
Personnel must be protected from falling. Observe the national, state, and local
regulations, and company policies when working above the floor level.
2.8
Sound pressure level
Fig. 3
The sound pressure level was measured at a distance of
3 ft
from the wire rope hoist.
The mean sound pressure level is calculated for one operating cycle (50% with maximum
permissible load, 50% without load).
Instead of stating an emission value based on a workplace, the values from Tab. 1 and
Tab. 2 at measuring distance
“h”
can be used.
Fig. 4
Type
[db (A)] +/-3
h [ft]
3 ft
7 ft
13 ft
26 ft
52 ft
YKA/SKA
76
73
70
67
64
YKB/SKB
76
73
70
67
64
YKC/SKC
78
75
72
69
66
YKE/SKE
78
75
72
69
66
Tab. 1
Type
[db (A)] +/-3
h [ft]
3 ft
7 ft
13 ft
26 ft
52 ft
YKA/SKA
76
70
64
58
52
YKB/SKB
76
70
64
58
52
YKC/SKC
78
72
66
60
50
YKE/SKE
78
72
66
60
50
Tab. 2
2.9
Fire safety
WARNING
Safety hazard.
Never use a powder extinguisher in the presence of high voltages.
Only fight the fire if this is possible without subjecting yourself to risk. Switch off the crane
if this is possible. Evacuate the area. Advise other persons on potential danger and call
for help.