7
Inspection and maintenance
142
07.2020
ba
-o
.2
.6
.0
-us
-3
.2
-ys
|
A1
18
67
50
1 Re
v A
E
With the block adjustment, set the switch-off at the top (see section 7.14 Adjusting the
switching points).
–
Turning clockwise: Switching point is shifted upwards
.
Reeve the loose rope end through the hook block according to the number of strands,
mount and fasten with the rope wedge and secure with a rope clamp (see section
4.13.2 "Rope fastening point").
Tighten the screws (8) for the clamping plates (9) once more (for tightening torques
see table).
Type
Thread size
Tightening torque
[lb
f
ft
]
YKA/SKA
M6
7
M10
30
YKB/SKB
M10
37
YKC/SKC
M10
37
M12
64
YKE/SKE
M12
M16
64
155
Tab. 31
Run the rope in with a partial load.
Check the geared limit switch and adjust if necessary (see section 7.14 Adjusting the
switching points).
If the new rope exhibits a twist after a certain operation time, untwist the rope immediately
(see section 4.13, "Rope reeving" and "Discarding a wire rope").