VR-5000 O
PERATING
M
ANUAL
51
2. Select the monitoring memory channel (“
DVR ch1
” or “
DVR ch2
”) by pressing the
[
MODE
(
ADRS
)
] key.
3. Press the [
F
] key momentarily, then press the [
STEP
(
PLAY
)
] key to start the monitor.
Notes:
• If you select the “
DVR ch1
” channel for playback, it will play back audio for 16 seconds
(irrespective of the actual recording time).
• If you select the “
DVR ch2
” channel for playback, it will play back audio for 8 seconds
(irrespective of the actual recording time).
F
IELD
S
TRENGTH
M
ETER
The
VR-5000
can provide display of the relative receiving signal strength on the LCD,
compared to some user-defined “baseline” field strength.
1. Press the [
F
] key momentarily, then press the [
4
(
SPL
)
] key.
2. Rotate the
DIAL
knob to set the cursor to the “
BASE FIELD STRENGTH
” menu option,
then press the [
ENT
(
SET
)
] key.
3. You will now observe the display of the cur-
rent signal strength (“
CURRENT
” row) and its
peak level (“
REFERENCE
” row). The first time
this is done, these levels will be the same (al-
though the “
CURRENT
” level will appear to
have a very slightly lower value, due to the
“damping” in the metering).
4. If you are resetting the reference level, press the [
0
(
NB
)
] key to equalize the peak level
to the current signal strength.
5. To cancel the Field Strength Meter displays the [
ENT
(
SET
)
] key momentarily; this
will save the peak level and let you exit to the menu mode.
6. Confirm that the cursor is on the “
CANCEL
” menu selection, then press the [
ENT
(
SET
)
]
key to exit to normal operation.
If you want to display the current signal level (for example, on a different channel), com-
pared to the reference level, use the following process:
1. Press the [
F
] key momentarily, then press the [
4
(
SPL
)
] key.
2. Rotate the
DIAL
knob to set the cursor to the “
CURRENT FIELD STR.
” menu option,
then press the [
ENT
(
SET
)
] key.
3. The current signal strength (“
CURRENT
” row) and the memorized peak level (“
REF-
ERENCE
” row) will be displayed.
4. To cancel the Field Strength Meter display, press the [
ENT
(
SET
)
] key momentarily, to
save the peak level and exit to menu mode.
5. Confirm that the cursor is on the “
CANCEL
” menu, then press the [
ENT
(
SET
)
] key to
exit to the normal operation.
Miscellaneous Features