VR-5000 O
PERATING
M
ANUAL
35
3. To change to a different PMS frequency pair, press the numerical keys on the keypad
corresponding to the PMS register you wish to use. For example, if you are on PMS
register “00” and wish to use PMS register “03,” press [
0
]
«
[
3
] while PMS scanning
is engaged. Scanning will begin on the new register without further action.
4. To reverse the direction of the scan (i.e. toward a
lower
frequency, instead of a higher
frequency), turn the
DIAL
knob one click in the counter-clock direction or press the
[
(
)]
key momentarily while the
VR-5000
is scanning. To revert to scanning toward
a higher frequency once more, rotate the
DIAL
knob one click clockwise or press the
[
(
)]
key momentarily.
5. Press the [
V/M
(
MW
)
] key to disable the PMS scanner, and return to VFO mode.
Adjusting the PMS Scanner (Including PMS Register Change)
1. Press the [
F
] key momentarily, then press the [
PMS
(
PMS SET
)
] key.
2. To change the PMS register on which you wish to scan, first confirm that the cursor is
pointing to “
PMS CH
,” then press the [
ENT
(
SET
)
] key.
3. Rotate the
DIAL
knob to select the new PMS register; now press the [
ENT
(
SET
)
] key.
4. If you only wish to change the PMS register, skip to step 7.
5. Rotate the
DIAL
knob to set the cursor to the “
MISC
” menu option, then press the
[
ENT
(
SET
)
] key.
6. Rotate the
DIAL
knob to set the cursor to the desired menu from the following list;
remember that these settings will only be applied during PMS operation.
ScanStop
: Selects the Scan Resume mode among “
HOLD
,” “
DELAY
,” and “
PAUSE
,”
as described previously. Press the [
•
(
BEEP
)
] key to change selections.
(1) In the “
HOLD
” mode, when a signal is received the scanner will hold for
2 second, then the scanner will stop.
(2) In the “
DELAY
” mode, when a signal is received the scanner will hold
until the signal disappears,
then the scanner will resume after 2 seconds.
(3) In the “
PAUSE
” mode, when a signal is received the scanner will hold
for 2 second, then scanner will resume after 2 seconds.
S-LvlScan
: The scanner will halt and pause on the frequency when there is a signal
strong enough to stops on.
VCS
:
Enables/disables the VCS (Voice Channel Scan) feature via pressing the [
•
(
BEEP
)
] key. When enable the VCS feature is enabled, the scanner will
only halt and pause on the frequency that is having the voice signal.
ATT
:
Enable/disable the RF signal Attenuator via pressing the [
•
(
BEEP
)
] key.
DSP
:
Turns the Digital Signal Processing system On or Off.
7. When you have made your selection(s), rotate the
DIAL
knob to select the “
END
”
menu option, then press the [
ENT
(
SET
)
] key.
8. Confirm that the cursor is now pointing to the “
WRITE
” menu option, and press the
[
ENT
(
SET
)
] key.
Scanning
Содержание VR-5000
Страница 62: ...VR 5000 OPERATING MANUAL 60 Note...