This feature a more refined and useful form of VFO scanning, allows you to establish sub-
band limits for scanning. This allows you to monitor only a portion of the wide frequency
range of the
VR-5000
, instead of sweeping the entire spectrum from 100 kHz to 2.6 GHz.
Programmable Memory Scan utilizes a pair of special memories to establish the upper and
lower scanning limits. Here is the procedure for setting up limited band scanning:
Programming
1. Press the [
F
] key momentarily, then press the [
PMS
(
PMS SET
)
] key to enable the
storage of the frequency pair into a PMS memory.
2. The cursor will be pointing at the “
PMS CH
” menu option; press the [
ENT
(
SET
)
] key.
3. If you want to program the frequency pair into the currently-selected PMS register
(shown on the right edge of the display), proceed to the next step; if you wish to choose
a different PMS register, press [
ENT
(
SET
)
], then use the [
(
)/
(
)] keys to select
a different memory register number. Then press [
ENT
(
SET
)
] to move on to the next
step.
4. Rotate the
DIAL
knob to set the cursor to the “
PMS TAG
” menu option.
5. Press the [
ENT
(
SET
)
] key to enable the programming of the name tag to the PMS
memory. To attach an alpha/numeric name tag to the PMS memory, program the alpha-
numeric “label” using the
DIAL
knob and keypad, as described previously; if you don’t
want to label this frequency pair register, press the [
ENT
(
SET
)
] key again.
6. When you have complete the creation of the label, press the [
ENT
(
SET
)
] key.
7. Now it’s time to set up the band limits. Rotate the
DIAL
knob to set the cursor to the
“
START F
” menu option, then press the [
ENT
(
SET
)
] key.
8. Set the VFO frequency to the Lower sub-band limit, then press the [
ENT
(
SET
)
] key.
9. Confirm that the cursor is on the “
END F
” menu, then press the [
ENT
] key.
10. Select the VFO frequency to the Upper sub-band limit, then press the [
ENT
(
SET
)
] key.
11. Rotate the
DIAL
knob to set the cursor to the “
END
” menu option, then press the
[
ENT
(
SET
)
] key.
12. Confirm that the cursor is on the “
WRITE
” menu option, press the [
ENT
(
SET
)
] key.
13. The PMS memory programming process is now completed.
Note:
50 PMS memories are available. You therefore can set upper and lower operation
limits on a number of bands, if you like.
Operation (Current PMS Register)
1. Press the [
PMS
(
PMS SET
)
] key to initiate PMS scanning in an upward direction.
2. If the scanner encounters a signal strong enough to open the squelch, the scanner will
halt and pause on that frequency. Scanning will resume according to the protocol you
selected in the previous discussion.
Scanning
Содержание VR-5000