Page 106
FT-2000D O
PERATING
M
ANUAL
M
EMORY
S
CAN
VFO
AND
M
EMORY
S
CANNING
1. Set the transceiver up in the memory mode by pressing
the [
V/M
] button, if necessary.
2. Rotate the Main [
SQL
] knob so that the background
noise is just silenced.
3. Press the [
M CH
] button momentarily.
When you press the [
M CH
] button, the Red LED im-
bedded within the switch should light up, indicating
that you are ready to choose a channel into which to
store the data.
A
DVICE
:
If the Red LED imbedded in the [
M CH
] button does
not light up, check to be sure that the orange lamp to
the right of the [
SUB VFO-B
] knob is not illuminated.
If it is, press the [
A/B
] button to make it go out, then
press the [
M CH
] button again.
4. Press and hold in the microphone’s [
UP
] or [
DWN
]
key for 1/2 second to start scanning in the specified
direction.
A
DVICE
:
If the scanner halts on an incoming signal, the deci-
mal point between the “MHz” and “kHz” digits of
the frequency display will blink.
If the incoming signal disappears, scanning will re-
sume in about five seconds.
5. To cancel the scanning, press the microphone’s [
UP
]
or [
DWN
] key momentarily.
A
DVICE
:
During Memory Group operation, only the channels
within the current Memory Group will be scanned.
If the scan has paused on a signal, pressing the
microphone’s [
UP
] or [
DWN
] key will cause scanning
to resume instantly.
If you press the microphone’s
PTT
switch during scan-
ning, the scanner will halt at once. Pressing the
PTT
switch during scanning will not cause transmission,
however.
You may select the manner in which the scanner re-
sumes while it has paused on a signal, using Menu item
“
041 GEnE SCN RSM
.” The default “
5Sec
5Sec
5Sec
5Sec
5Sec
” setting
will cause the scanner to resume scanning after five
seconds; you may change it, however, to resume only
after the carrier has dropped out, if you like See page
119.
Main [SQL] Knob
Q
UICK
P
OINT
:
If you have no interest in scanning, and wish to prohibit
the microphone’s [
UP
]/[
DWN
] keys from initiating scan-
ning, you may disable scanning control from the micro-
phone using Menu item “
040 GEnE MIC SCN
” (set it to
“
Off
Off
Off
Off
Off
”).
[SUB VFO-B] Knob
[V/M] Button
[M CH] Button
[A/B] Button
Содержание FT-2000D
Страница 7: ...Page 5 FT 2000D OPERATING MANUAL NOTE ...
Страница 13: ...Page 11 FT 2000D OPERATING MANUAL CONNECTION OF MICROPHONE AND HEADPHONE INSTALLATION AND INTERCONNECTIONS ...
Страница 43: ...Page 41 FT 2000D OPERATING MANUAL NOTES ...
Страница 75: ...Page 73 FT 2000D OPERATING MANUAL ENHANCING TRANSMIT SIGNAL QUALITY NOTE ...
Страница 133: ...Page 131 FT 2000D OPERATING MANUAL MENU MODE NOTE ...
Страница 137: ...Page 135 FT 2000D OPERATING MANUAL NOTE ...
Страница 138: ...Page 136 FT 2000D OPERATING MANUAL NOTE ...