Chassis Management Displays
Field
Means
Suspended
The processor module failed to obtain the software load
image because the information in control storage was
invalid or corrupt. To correct this condition, you can change
the information in the initialization records with the
DEFINE CHASSIS SLOT commands, described in Chapter
4.
Run
The processor module is not operational because it has been
Inhibited
suspended, or "held, " either because a user pushed the reset
button on the front panel once, or a user entered the RESET
CHASSIS HOLD command for this slot.
Diagnostics The processor module is running diagnostic programs.
Failed
The processor module was running diagnostics programs,
and these programs failed. If this status appears, contact
your Xyplex representative for more information.
Not
The Single Chip Microcontroller on the module responded
Responding to the request for status, but the operational software did not.
When this status appears, other fields in the display,
including Installed Memory, Link Mappings, and Uptime
do not have status. If the module in the slot returns the status
Not Responding, wait 30 seconds and enter the Slot Status
command for the module in this slot again. If the module
still returns the status Not Responding, contact your Xyplex
representative.
Processor
Module
The model number and revision number of the processor module in this
slot. This display shows a model 410 bridge. If no processor module
exists in this slot, then N/A (not applicable) appears in this field.
The type and revision number of the I/O module in this slot. This display
shows a four port LAN bridge/router, the BR/412. If no I/O module exists
in this slot, then N/A (not applicable) appears in this field.
I/O Module
The amount of memory installed on the processor module.
Installed
Memory
The Ethernet address of the module or module set.
802.x Address
The Internet address of the module or module set.
IP Address
The version of the firmware running on this processor module.
Firmware
Version
The serial number of the processor module.
Proc Mod.
Serial #
94