Chassis Management Displays
SHOW/MONITOR [SERVER] CHASSIS POWER SUMMARY
Display the summary information about power provided and power consumed
The SHOW/MONITOR [SERVER] CHASSIS POWER SUMMARY
command displays the total wattage that each PS/130 power supply in the
chassis provides, the actual power consumed, and the estimated wattage
that each slot in the chassis consumes.
Notes
If the power supplies in the chassis are unmanaged PS/120 power supplies,
this display includes only the estimated power consumed by each slot.
Privilege
Level
Show/Nonprivileged Monitor/Privileged
Syntax
SHOW | MONITOR [SERVER] CHASSIS POWER SUMMARY
Power
Hardware
+5V
+12V
-12V
Total
-----
--------------
------
------
------
------
1
PS/130
100.0W
35.0W
35.0W
150.0W
2
PS/130
100.0W
35.0W
35.0W
150.0W
------
------
------
------
Max. Power Provided
200.0W
70.0W
70.0W
300.0W
Power Consumed
70.0W
35.0W
45.0W
130.0W
------
------
------
------
Power Available
130W
35.0W
45.0W
170.0W
Slot
Hardware
+5V
+12V
-12V
Total
-----
---------------
------
------
------
------
1
Unknown- AC/119
0.0W
0.0W
0.0W
0.0W
2
BR/410 - BR/412
17.5W
9.6W
0.0W
27.1W
3
TS/720 - TS/721
12.5W
4.8W
4.8W
22.1W
4
TS/720 - TS/722
13.0W
6.0W
6.0W
25.0W
5
TS/720 - TS/723
13.5W
7.2W
7.2W
27.9W
6
TS/720 - TS/724
14.5W
7.2W
7.2W
28.9W
------
------
------
------
Worst Case Power
70.0W
35.0W
25.0W
130.0W
Field
Means
The number of each power supply in the chassis. (The hardware type and
voltage levels which follow appear only for managed power supplies. If
the chassis contains unmanaged power supplies, only the slot
information appears in the display.)
Power
0020
87