Managing the Operational Link Map
Figure 3-5 shows a Chassis Slot Status display for a terminal server in slot 3 with with the
default connections in the Link Mappings section of the display.
Slot 3 Status:
Operational
Firmware Version:
410000
Processor Module:
TS/720
Proc Mod. Serial #:
000087956
I/O Module
TS/723
I/O Mod. #:
000089765
Installed Memory:
4 Megabytes
SCM Version:
100000
802.x Address
08-00-87-01-C7-65
Uptime:
5 11:27:04
IP Address:
140.179.80.113
Link Mappings
Worst
Case
Power
--------------------
---------------------
Ethernet 1 Segment A
+5V
13.5W
+12V
7.2W
-12V
7.2W
---------------------
Total
37.9W
Figure 3-5. A Show Chassis Slot Status Display For a Terminal Server 720
To change the connection to segment B or C, you can enter a command such as the
following, which specifies segment B:
Xyplex>> define chassis slot ethernet 1 segment b
XYPLEX
-
1901-WARNING-This
command
will
change
the
ethernet
segment NOW!
Press
<Return>
to
modify
parameter,
any
other
key
to
abort.
Xyplex>>
The link map looks like the one in Figure 3-6 after the change.
38
0020