4
WIRING AND GROUNDING
Install, ground and wire ac-
cording to local and National
Electrical Code Requirements.
Install an all leg disconnect
switch near the pump.
Disconnect and lockout electri-
cal power before installing or
servicing the pump.
Electrical supply
MUST
match pump’s name-
plate specifications. Incorrect voltage can cause
fire, damage to the motor and voids the war
-
ranty.
Motors not protected
MUST
be provided with
contactors and thermal overloads for single
phase motors, or starters with heaters for three
phase motors. See motor nameplate.
Use only copper wire to motor and ground. The
ground wire
MUST
be at least as large as the wire to
the motor. Wires should be color coded for ease of
maintenance.
Follow motor manufacturer’s wiring diagram on the
motor nameplate or terminal cover carefully.
FAILURE TO PERMANENTLY
GROUND THE PUMP, MOTOR AND
CONTROLS BEFORE CONNECTING
TO ELECTRICAL POWER CAN CAUSE
SHOCK, BURNS OR DEATH.
COUPLING ALIGNMENT
FAILURE TO DISCONNECT AND
LOCKOUT ELECTRICAL POWER
BEFORE ATTEMPTING ANY
MAINTENANCE CAN CAUSE SEVERE
PERSONAL INJURY.
are filled solid. Allow grout to harden 48 hours before
fully tightening foundation bolts.
Tighten pump and motor hold-down bolts before
aligning shaft or connecting the piping to pump.
PIPING
Piping should be no smaller than pump’s discharge
and suction connections and kept as short as possible,
avoiding unnecessary fittings to minimize friction
losses.
All piping
MUST
be independently supported and
MUST NOT
place any piping loads on the pump
NOTICE: DO NOT FORCE PIPING INTO PLACE
AT PUMP SUCTION AND DISCHARGE
CONNECTIONS.
All pipe joints
MUST
be airtight.
Piping – Suction
For suction lifts over 15 ft. (4.6 m), consult pump per-
formance curve for net positive suction head required
(NPSH
R
).
If a pipe size larger than pump suction is required,
an eccentric pipe reducer, with the straight side up,
MUST
be installed at the pump suction.
If pump is installed below the liquid source, install
a gate valve in the suction for pump inspection and
maintenance.
NOTICE: DO NOT USE THE GATE VALVE TO
THROTTLE PUMP. THIS MAY CAUSE LOSS
OF PRIME, EXCESSIVE TEMPERATURES
AND DAMAGE TO PUMP, VOIDING
WARRANTY.
If the pump is installed above the liquid source, the
following
MUST
be provided:
To avoid air pockets, no part of the piping should
be above the pump suction connection.
Slope the piping upward from liquid source.
Use a foot valve or check valve
ONLY
if neces-
sary for priming or to hold prime during intermit-
tent duty.
The suction strainer or suction bell
MUST
be at
least three times the suction pipe diameter area.
Insure that the size and minimum submergence
over suction inlet is sufficient to prevent air from
entering pump through a suction vortex. See Fig-
ures 2 through 5.
Piping – Discharge
Install a check valve suitable to handle the flow, liq
-
uids and to prevent backflow. After the check valve,
install an appropriately sized gate valve to be used to
regulate the pump capacity, pump inspection and for
maintenance.
When required, pipe increaser should be installed
between the check valve and the pump discharge.
Figure 4
Figure 5
H min.
D
D
H min.
D
D
1.5D
min.
3.0D
min.
H min.
D min.
2
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
H = Min. Submergence in feet
H
1 2 3 4 5 6 7 8 9 10111213141516
V
V = V elocity in feet per second
= GPM x 0.321
Area
PM x 0.4085
D
2
Figure 2
Figure 3
WARNING
Hazardous voltage
can shock, burn or
cause death.
WARNING
Hazardous
voltage
Hazardous machinery
can cause personal
injury or death.
WARNING