CLS CLS is a sensor for detection of water in the oil housing. The sensor initiates an alarm
when the oil contains approximately 35% water. The sensor is installed in the bearing
housing/bearing holder with its sensing part in the oil housing. The CLS sensor is not
applicable to Ex-approved pumps.
NOTICE:
The CLS sensor body is made of glass. Handle the sensor with care.
One CLS and one FLS sensor can be used in the same pump, if they are connected in
parallel.
The data plate
The data plate is a metal label located on the main body of the products. The data plate
lists key product specifications. Specially approved products also have an approval plate.
2
13
12
14
22
21
20
17 18
19
16
15
9
10
11
8
7
6
5
4
3
1
23
24
WS006257A
1.
Curve code/Propeller code
2.
3.
Product number
4.
Country of origin
5.
Additional information
6.
Phase; type of current; frequency
7.
Rated voltage
8.
Thermal protection
9.
Thermal class
10. Rated shaft power
11. International standard
12. Degree of protection
13. Rated current
14. Rated speed
15. Maximum submergence
16. Direction of rotation: L=left, R=right
17. Duty class
18. Duty factor
19. Product weight
20. Locked rotor code letter
21. Power factor
22. Maximum ambient temperature
23. Read installation manual
24. Notified body. Only for EN-approved Ex-products