7.4 The pump runs but the motor protection trips
DANGER: Crush Hazard
Moving parts can entangle or crush. Always disconnect and lock out power before
servicing to prevent unexpected startup. Failure to do so could result in death or serious
injury.
NOTICE:
Do NOT override the motor protection repeatedly if it has tripped. Doing so may result in
equipment damage.
Cause
Remedy
The motor protection is set too low.
Set the motor protection according to the data plate and if applicable the
cable chart.
The impeller is difficult to rotate by
hand.
• Clean the impeller.
• Clean out the sump.
• Check that the impeller is properly trimmed.
The drive unit is not receiving full
voltage on all three phases.
• Check the fuses. Replace fuses that have tripped.
• If the fuses are intact, then notify a certified electrician.
The phase currents vary, or they are
too high.
Contact the local sales and service representative.
The insulation between the phases
and ground in the stator is defective.
1. Use an insulation tester. With a 1000 V DC megger, check that the
insulation between the phases and between any phase and ground is >
5 megaohms.
2. If the insulation is less, then do the following:
Contact the local sales and service representative.
The density of the pumped fluid is too
high.
Make sure that the maximum density is 1100 kg/m3 (9.2 lb/US gal)
• Change the impeller, or
• Change to a more suitable pump
• Contact the local sales and service representative.
The ambient temperature exceeds the
maximum ambient temperature.
The pump must not be used for such an application.
There is a malfunction in the overload
protection.
Replace the overload protection.
If the problem persists, contact the local sales and service representative. Always state the
serial number of your product, see
7.5 The pump delivers too little or no water
DANGER: Crush Hazard
Moving parts can entangle or crush. Always disconnect and lock out power before
servicing to prevent unexpected startup. Failure to do so could result in death or serious
injury.
NOTICE:
Do NOT override the motor protection repeatedly if it has tripped. Doing so may result in
equipment damage.
Cause
Remedy
The impeller rotates in the wrong
direction.
• If it is a 3-phase pump, then transpose two phase leads.
• If it is a 1-phase pump, then do the following:
Contact the local sales and service representative.