5
TROUBLESHOOTING CHART
CONVERSION TABLE
WARRANTY
XYLEM LIMITED WARRANTY WARRANTS THIS PRODUCT TO BE FREE OF DEFECTS AND WORK-
MANSHIP FOR A PERIOD OF 1 YEAR FROM DATE OF MANUFACTURE. THE WARRANTY IS EXCLU-
SIVE AND IN LIEU OF ANY AND ALL OTHER EXPRESS OR IMPLIED WARRANTIES, GUARANTEES,
CONDITIONS OR TERMS OF WHATEVER NATURE RELATING TO THE GOODS PROVIDED HERE-
UNDER, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HEREBY EXPRESSLY DISCLAIMED
AND EXCLUDED. EXCEPT AS OTHERWISE PROVIDED BY LAW, BUYER’S EXCLUSIVE REMEDY
AND SELLER’S AGGREGATE LIABILITY FOR BREACH OF ANY OF THE FOREGOING WARRANTIES
ARE LIMITED TO REPAIRING OR REPLACING THE PRODUCT AND SHALL IN ALL CASES BE LIMIT-
ED TO THE AMOUNT PAID BY THE BUYER HEREUNDER. IN NO EVENT IS SELLER LIABLE FOR ANY
OTHER FORM OF DAMAGES, WHETHER DIRECT, INDIRECT, LIQUIDATED, INCIDENTAL, CONSE-
Symptom
Possible Cause(s)
Corrective Action
Pump will not prime or retain
prime after operating
• Air leak in suction line
• Defective check valve
• Upper housing leaking
• Suction lift too high
• Debris in check valve(s)
• Repair or replace
• Replace
• Tighten bolts
• Lower pump
• Clean check valve(s)
Pump runs but no fluid
• Faulty suction piping
• Defective check valve
• Suction lift too high
• Clogged inlet
• Inlet line valve closed
• Repair or replace
• Replace
• Lower pump
• Clean or replace
• Open valve
Motor runs too hot
• Voltage incorrect
• Insufficient ventilation for motor
• Check voltage
• Insure proper ventilation
Flow rate is low
• Piping or hose is damaged
• Clogged check valve
• Worn check valve
• Voltage incorrect
• Tank over pressurized
• Clean or replace
• Clear obstruction
• Replace
• Check voltage
• Check tank pressure
Pump leaks
• Upper housing loose
• Pistons loose
• Pump head loose on motor
• Switch loose
• Defective Diaphragm
• Tighten screws
• Tighten pistons
• Tighten pump head
• Tighten switch
• Replace
Pump will not run
• No electricity
• Defective pressure switch
• Motor has open circuit
• Thermal protector has cut off
• Check connections, fuse, breakers
• Replace switch
• Replace
• Allow motor to cool 15-30 min
TO CONVERT
TO
MULTIPLY BY
Gallons, U.S.
Liters
3.785
Liters
Gallons, U.S.
0.264
Pounds/Square Inch
Bar
0.069
Bar
Pounds/Square Inch
14.5
Fahrenheit
Celsius
(°F-32) .556
Celsius
Fahrenheit
(°C X 1.8) + 32
TABLEAU DE CONVERSION / UMRECHNUNGSTABELLE / TABELLA DI CONVERSIONE
CONVERSIETABEL / KONVERTERINGSTABELL / TABLA DE CONVERSIÓN
QUENTIAL, PUNITIVE, EXEMPLARY OR SPECIAL DAMAGES, INCLUDING BUT NOT LIMITED TO
LOSS OF PROFIT, LOSS OF ANTICIPATED SAVINGS OR REVENUE, LOSS OF INCOME, LOSS OF
BUSINESS, LOSS OF PRODUCTION, LOSS OF OPPORTUNITY OR LOSS OF REPUTATION. THIS
WARRANTY IS ONLY A REPRESENTATION OF THE COMPLETE LIMITED WARRANTY. FOR A DE-
TAILED EXPLANATION, PLEASE VISIT US AT www.xylem.com/en-us/support/, CALL OUR OFFICE
NUMBER LISTED, OR WRITE A LETTER TO YOUR REGIONAL OFFICE.
RETURN PROCEDURE
Warranty returns are conducted through the place of purchase. Please
contact the appropriate entity with a receipt of purchase to verify date.