GENERAL SAFETY INFORMATION

Protect yourself and others by observing all safety information. Shut off 
power and drain pressure from system prior to service.

Mounting

The FLOJET 2840 Series Water Pressure System should be mounted in 
a dry and adequately ventilated area.
Select a location where the plumbing is as direct as possible and the 
inlet strainer is visible and accessible for cleaning.
The unit can be deck or bulkhead mounted. If bulkhead mounted, the 
pump head should be down or lower than the motor.
Fasten base securely with the four rubber mounting feet assembled to 
base as shown below.

Plumbing

Fasten strainer in a visible and accessible location for future cleaning. 
Use 3/4” (19 mm) I.D. hose between pump inlet & strainer. Connect 
strainer inlet to water supply line from tank and clamp all hose connec-
tions securely to avoid air leaks.
City water supply may be connected at any location in the pressurized 
cold water line.

City water inlet

Autofill tank valve, 

plumb to tank

Do not plumb auto fill 

to pump suction line

Water heater

Check valve

Water Pressure 

System

Water

tank

ELECTRICAL

W A R N I N G

W A R N I N G

W A R N I N G

RISK OF AN ELECTRICAL SHOCK!

When wiring an electrically driven pump, follow all electrical and safety 
codes, as well as the most recent National Electrical Code (NEC) and 
the Occupational Safety and Health Act (OSHA).

RISK OF PRODUCT DAMAGE!

Make certain the power source conforms to the pump voltage. Be sure 
all power is disconnected before installation or removal.
For 12 VDC, 24 VDC and 32 VDC models, the red wire is positive and 
black is negative. Use the maximum recommended fuse for pump pro-
tection. Recommended fuse amp rating is located on pump label. Fail-
ure to provide correct overload device may result in motor failure.
For 115 VAC models plug AC cord into a conventional 115V AC outlet.

OPERATION

IMPORTANT −

 For correct operation, the tank must be properly pres-

surized on the air side before pump is started. Follow instructions on 
the tank label and check air pressure after filling and before starting the 
pump. The air valve is standard tire valve. Compressed air hose or hand 
pump may be used to pressurize. Pressure can be reduced by pressing 
the center pin in the valve.
To start up the Water Pressure System, make sure water supply tank is 
at least 1/4th full and is open to pump inlet. Open all valves or taps on 
outlet side to purge air from the system. Turn power on to the pump, 
pump will start up. Allow to pump for a minute or until all the air has 
been purged from the system. Close all valves in the system, the pump 
will pressurize the tank, shut off and operate automatically to maintain 
pressure in the system.
To completely fill the pressure tank for maximum volume, shut off pow-
er to pump and open faucet (or valve) closest to tank. Trapped air will 
be expelled. Turn on power to pump.

DO NOT USE PUMP IN A FLAMMABLE ENVIRONMENT. DO NOT PUMP GASOLINE, PET-

ROL OR FLUIDS WITH FLASH POINT BELOW 100°F (37.8°C). DOING SO MAY RESULT IN 

EXPLOSION WHICH COULD CAUSE PERSONAL INJURY, DEATH OR PROPERTY DAMAGE.

Do not use Water Boost System if it presents some damage such as burned or broken 

pressure switch, exposed wire and/or contacts.

WARNING: DISCONNECT POWER TO PUMP AND OPEN VALVE TO

RELIEVE WATER PRESSURE PRIOR TO SERVICING PUMP

2

1

4

6

9

3

A

5

B

A

B C

D

C

7

Includes items 1 thru 4

8

Содержание FLOJET 2840 Series

Страница 1: ...a di potenziamento dell acqua INFORMAZIONI SU INSTALLAZIONE E SERVIZIO Sistema de refuerzo de agua INFORMACI N DE INSTALACI N Y SERVICIO Wasser Booster System INSTALLATIONS UND SERVICEINFORMATIONEN Wa...

Страница 2: ...1 GL 4 2 L Air Pressure Setting 25 PSI 1 7 Bar Note The 12 24 and 32 VDC models meet the USCG Electrical Re quirement Title 33 Chapter I Part 183 Subpart 1 meets ISO 8846 Ma rine Ignition Protection...

Страница 3: ...ositive and black is negative Use the maximum recommended fuse for pump pro tection Recommended fuse amp rating is located on pump label Fail ure to provide correct overload device may result in motor...

Страница 4: ...Rubber Feet by pulling out and sliding to the rear and fol low step 3 9 Rotate Lower Housing 4 so access Rubber Grommet foot notch is aligned with Cam Bearing Set Screw 4 C loosen set screw with a 1...

Страница 5: ...hot Voltage incorrect Insufficient ventilation for motor Check voltage Insure proper ventilation Flow rate is low Piping or hose is damaged Clogged check valve Worn check valve Voltage incorrect Tank...

Страница 6: ...s les consignes de s curit Couper l alimentation et vidanger la pression du syst me avant l entretien Montage Le syst me de pression d eau de la s rie FLOJET 2840 doit tre mont dans un endroit sec et...

Страница 7: ...me 2 Retirez les deux vis visibles du pressostat situ es de chaque c t du pressostat 9 NE PAS R GLER LA VIS T TE ALLEN AU CENTRE DE L INTERRUPTEUR Logement sup rieur 1 3 Desserrez mais NE retirez PAS...

Страница 8: ...NTRAIRE PAR LA LOI LE RECOURS EXCLUSIF DE L ACHETEUR ET LA RESPONSABILIT GLOBALE DU VENDEUR EN CAS DE VIOLATION DE L UNE DES GARANTIES PR C DENTES SONT LIMIT S LA R PARATION OU AU REMPLACE MENT DU PRO...

Страница 9: ...sschutzgesetz OSHA GEFAHR VON PRODUKTSCH DEN Stellen Sie sicher dass die Stromquelle der Pumpenspannung entspricht Stellen Sie sicher dass die Stromversorgung vor der Installation oder Entfernung getr...

Страница 10: ...hrauben mit einem Kreuzschlitzschraubendreher und ziehen Sie den Nocken 4 B von den inneren Kolben 3 A ab Beide Kolben 3 A C sollten ersetzt werden wenn eine neue Membran 3 13 installiert wird Motor 5...

Страница 11: ...DER VOLLST NDIGEN BESCHR NKTEN GARANTIE F R EINE DETAILLIERTE ERKL RUNG BESUCHEN SIE UNS BITTE UNTER www xylem com de de support RUFEN SIE UNSERE AUFGEF HRTE B RONUMMER AN ODER SCHREIBEN SIE EINEN BRI...

Страница 12: ...stema la pompa pressurizzer il serbatoio si spegner e funzioner automaticamente per mantenere la pressione nel sistema Per riempire completamente il serbatoio a pressione per il volume massimo interro...

Страница 13: ...8 Posizionare correttamente l O ring nella valvola di ritegno 2 e inserire la valvola di ritegno 2 nell alloggiamento superiore 1 Alloggiamento superiore 1 9 Posizionare l alloggiamento superiore 1 so...

Страница 14: ...rgt voor een soepele waterstroom van een straaltje naar een volledige stroom Meestal gebruikt in grote jachten campers en busconversies waar een hoge volume stroom vereist is voor meerdere armaturen e...

Страница 15: ...1 4e vol is en open staat voor de pompinlaat Open alle kleppen of kranen aan de uitlaatzijde om lucht uit het systeem te verwijderen Schakel de stroom naar de pomp in de pomp zal opstarten Laat een mi...

Страница 16: ...de keerklep 2 in de bovenste be huizing 1 Bovenste behuizing 1 9 Plaats de bovenste behuizing 1 bovenop de onderste behuizing 4 A en draai de zeskantbouten 30 in lbs torsie door de bovenste behuizing...

Страница 17: ...ontering FLOJET 2840 seriens vattentryckssystem ska monteras i ett torrt och tillr ckligt ventilerat utrymme V lj en plats d r r rdragningen r s direkt som m jligt och inloppssilen r synlig och tillg...

Страница 18: ...4 Slang Barb 1 Servicesatsen inneh ller 2 3 8 och drivkamenheten TA IS R Tryckbrytare 9 1 Koppla bort str mmen till pumpen och ppna en kran eller ventil f r att minska systemtrycket 2 Ta bort de tv s...

Страница 19: ...tska Defekt sugr r Defekt backventil Suglyft f r h gt T ppt inlopp Inloppsventilen st ngd Reparera eller byt ut Byta ut S nk pumpen Reng r eller byt ut ppna ventilen Motorn g r f r varm Sp nning felak...

Страница 20: ...SERIE 2840 RV MARINO SISTEMA DE IMPULSI N DE AGUA ES Descripci n El sistema de refuerzo de agua de la serie FLOJET 2840 est dise ado para proporcionar una presi n de agua constante y un flujo generoso...

Страница 21: ...las del sistema la bom ba presurizar el tanque se apagar y operar autom ticamente para mantener la presi n en el sistema Para llenar completamente el tanque de presi n para el volumen m ximo apague la...

Страница 22: ...e el cojinete de leva 4 B sobre los pistones internos 3 C y apriete con cuatro tornillos de cabeza Phillips torsi n de 18 lb pulg Carcasa inferior 4 a motor 6 Cubra el eje del motor con grasa antes de...

Страница 23: ...A REPARAR O REEMPLAZAR EL PRODUCTO Y SE LIMITAR EN TODOS LOS CASOS A LA CANTIDAD PAGADA POR EL COMPRADOR EN CONFORMIDAD CON EL PRESENTE ACUERDO EN NING N CASO EL VENDEDOR ES RESPONSABLE DE CUALQUIER...

Страница 24: ...Innovation Park London Road Harlow Essex CM17 9LX Xylem Inc AUSTRALIA 2 2 Capicure Drive Eastern Creek NSW 2766 Xylem Inc CHINA 30 F Tower A 100 Zunyi Road Shanghai 200051 www xylem com flojet 2022 Xy...

Отзывы: