5-1
Chapter 5 – Maintenance
The 9460/9462/9460KP/9462KP was designed to withstand the harsh environment of the
factory floor. Routine maintenance can help keep your system in good operating condition.
Preventive maintenance consists of several basic procedures that will greatly reduce the
chance of system malfunction. Schedule preventive maintenance along with the regular
equipment maintenance to minimize down time.
Preventive Maintenance
Here are some preventive measures you can take:
•
Clean the monitor screen using a non-residue cleaner such as a mild window cleaning
solution or CRT screen cleaner. Take care not to scratch the screen face.
•
Clean or change the fan filter periodically to ensure that the air circulating in the unit
is clean. Wash the filter with warm water and dish soap, and let it air dry. Do not
scrub the filter, and do not re-install it into the unit until it is completely dry.
•
Base your maintenance schedule on the type of environment the system is in (i.e., if
the area is dusty, schedule maintenance more often than if it is a dry, clean area).
Check the filter often to determine if it needs to be changed ahead of schedule.
•
Remove dust and dirt from PC components. If dust builds up on heat sinks and cir-
cuitry, an obstruction of heat dissipation could cause the unit to malfunction. If dust
reaches the electronic boards, a short circuit could occur.
•
Check the connections to I/O modules, especially in environments where shock could
loosen the connections. Check to see that all plugs, sockets, terminal strips, and mod-
ule connections are solid.
•
Remove unnecessary articles, such as drawings or manuals, from the unit. They can
obstruct air flow and create hot spots, which causes the system to malfunction.
•
Do not place noise generating equipment near the 9460/9462.
•
Stock spare parts
to minimize down time resulting from part failure. Spare parts
stocked should be 10 percent of the number of each unit used. Main CPU cards
should have one spare each. Each power supply should have a back-up. In applic a-
tions where immediate operation of a failed system is required, you may need to stock
an entire spare computer module. Refer to the Spare Parts List in this chapter.
•
Replace the module with the correct type. If the new module solves the problem but
the failure reoccurs, check for inductive loads that may be generating voltage and cur-
rent spikes and may require external suppression.