background image

AirWave Octo

8

AirWave Octo Service and Repair Manual

 

Disassembly Procedures

General Guidelines

  Prior to performing any disassembly, check to ensure that 

the service facility is well equipped with all the tools and 

parts needed to perform a complete service from start to 

finish.  DO NOT attempt to perform the service unless all 

of the required tools and parts are available.

  All o-rings are classified as being either dynamic or 

static.  

Dynamic  

o-rings are those which sustain friction 

and movement, as they are either mounted directly onto 

a moving part, or create a seal against a moving part.  

Static  

o-rings simply create a seal between two non-

moving parts, and are therefore less subject to wear than 

dynamic  o-rings.  After passing close inspection, static 

 

O-rings may sometimes be reused, although this is not 

necessarily recommended.  Dynamic  O-rings must be 

automatically discarded and replaced with every service, 

regardless of age or appearance.

  Refer to the schematic and parts list while performing 

these procedures.  Each part is identified by its reference 

number shown on the drawing the first time it is referred 

to in the procedure.  

  Do not attempt to reuse parts that are designated to 

be automatically discarded and replaced with the parts 

provided in the overhaul parts kit.  These parts should be 

shown to the customer, however, to ensure their confi

-

dence and satisfaction that complete overhaul service has 

been performed.

  Inspect all reusable parts as directed, either during or im-

mediately following the disassembly procedures.  When 

in doubt, compare the part with one that is new to best 

determine its condition.

3

SECTION

Содержание Airwave Octopus

Страница 1: ...Service Repair Manual rev 06 08 SERVICE AND REPAIR MANUAL AIRWAVE OCTO PN RG320...

Страница 2: ...External Inspection 6 Immersion Leak Test 6 Intermediate Pressure Test 7 Section 3 Disassembly Procedures General Guidelines 8 Section 4 Reassembly Procedures General Guidelines 12 Section 5 Final Tes...

Страница 3: ...product it is extremely critical that it receives service according to the procedures outlined in this manual on a regularly scheduled basis at least once a year with normal or infrequent use NOTE A...

Страница 4: ...sult from improper use of this tool Be sure to follow the instructions provided in this manual NOTE XS Scuba especially endorses and recommends the Jaws Gripmaster Bench Vise available from Peter Buil...

Страница 5: ...ol PN 20 500 200 Tech Driver IPG PN 20 165 111 O ring Tool Set PN 10 125 400 1 4 Slotted Screwdriver PN 11 465 500 1 4 Nut Driver PN 11 168 500 Small 02 Blade Screwdriver PN 11 133 500 Cristo Lube PN...

Страница 6: ...r damage that exposes the brass beneath the finish CAUTION Do not clean any parts that show damage to their finish inside an ultrasonic cleaner 4 Closely examine all parts of the first stage for any o...

Страница 7: ...xceeds 400 psi may result in damage or rupture of the test gauge or LP hose and could cause serious personal injury 2 Slowly open the supply valve to pressurize the first stage Closely monitor the IP...

Страница 8: ...ngs After passing close inspection static O rings may sometimes be reused although this is not necessarily recommended Dynamic O rings must be automatically discarded and replaced with every service r...

Страница 9: ...a n open end wrench turn the inlet fitting counter clockwise to loosen and unscrew it completely by hand to remove Closely examine the plastic threads and overall condition of the inlet fitting and re...

Страница 10: ...tor counter clockwise from the air barrel 15 and carefully remove the O ring 21 with a plastic tool 13 Turn the air barrel over to allow the balance shuttle cap 20 and LP spring 19 to drop out see Fig...

Страница 11: ...ace to keep it isolated from other metal parts 21 Gently pull the exhaust deflector 26 off from the second stage housing to expose the exhaust valve 25 for inspection 22 Closely inspect the exhaust de...

Страница 12: ...G 11 PN MS150 to be used exclusively for the lubrication and dressing of O rings and other internal parts Christo Lube provides superior lubrication to that of silicone grease especially in high press...

Страница 13: ...e tab engages in the hole next to it Then gently press the opposite leg into place so the the other tab engages in the opposite hole When done cor rectly the lever pad should rest flush against the fl...

Страница 14: ...te leg engages with the opposite side The lever should now be standing up when released pointing toward the venturi deflector See Fig 14 11 While holding the second stage housing right side up with th...

Страница 15: ...t clockwise while closely watching the lever When the lever starts to drop stop do not turn the orifice any further This will indicate that the orifice has made contact against the LP seat See Fig 20...

Страница 16: ...ate pressure exceeds 155 170 psi ensure that a fully assembled and properly adjusted second stage is connected to the first stage before pressurizing Failure to relieve intermediate pressure that exce...

Страница 17: ...justing Tool and mate the opposite fitting of the tool onto the inlet fitting of the second stage Pull back the knurled knob to retract the slotted drive and tighten the tool clockwise onto the inlet...

Страница 18: ...stage valve and may impair the regulator s performance 8 When the second stage is properly adjusted with no leaks or lever slack depressurize and purge the system to dis connect the LP hose 9 Reconne...

Страница 19: ...e to slower bubble formation that occurs in smaller leaks Disassemble the regulator at the source of the leak to check sealing surfaces assembly sequence and component positioning in order to correct...

Страница 20: ...ermediate pressure 1 Refer to first stage troubleshooting 2 Orifice incorrectly adjusted 2 Reset to preliminary setting and readjust 3 Lever is damaged 3 Replace with new 1 Lever is slack or orifice i...

Страница 21: ...rifice 10 RP320 10 1 O ring 11 RP320 11 1 Mouthpiece 12 RP320 12 1 Tie Strap 13 RP320 13 1 Housing 14 RP320 14 1 Lever Pad 15 RP320 15 1 Air Barrel 16 RP320 16 1 LP Seat 17 RP320 17 1 Poppet 18 RP320...

Отзывы: