AirWave Octo
20
AirWave Octo Service and Repair Manual
1. Excessive intermediate pressure.
1. Refer to first stage troubleshooting
2. Damaged or worn LP seat.
2. Replace with new.
3. Damaged orifice sealing surface.
3. Replace with new.
4. Damaged orifice O-ring.
4. Replace with new.
5. Orifice incorrectly adjusted.
5. Reset to preliminary setting and
readjust.
6. Poppet spring damaged.
6. Replace with new.
1. Insufficent intermediate pressure.
1. Refer to first stage troubleshooting
2. Orifice incorrectly adjusted.
2. Reset to preliminary setting and
readjust.
3. Lever is damaged.
3. Replace with new.
1. Lever is slack, or orifice incorrectly adjusted. 1. Reset to preliminary settings and
readjust.
2. Lever is bent.
2. Replace with new.
1. Exhaust valve worn or damaged.
1. Replace with new.
2. Mouthpiece worn or damaged.
2. Replace with new.
Symptom
poSSible CauSe
treatment
Freeflow or leakage
Excessive Inhalation Resistance
or Hesitation
Insufficient airflow when
purge is depressed
Troubleshooting Guide
Second Stage
Water entering second stage