1.
Usage of Four Parameters:
Proportion parameter (Kp), integral parameter (Ki), differential
parameter (Kd), control proportion band (Diff).
Parameter P
is the proportion parameter.
Parameter I
is the integral parameter, mainly used to remove net difference.
Parameter D
is the differential parameter, mainly used to control signal’s change trend.
Temperature Control Band Means:
in the assigned band, to carry out PID control, beyond the
band does not carry out PID control.
2.
Temperature Control Cycle:
When carrying out PID adjustment, the output will carry on
heating according to the duty cycle got by PID output value, this period is called
Temperature
Control Cycle
3
. Control Specialties:
The band of the PID adjustment is: (QD-Diff QD + Diff), when the
temperature is lower than QD-Diff, controller goes on heating, when temperature is higher than
QD + Diff, the controller will stop heating.
The Control Curve of PID is Shown Below:
Each parameter’s reference value: Kp=20/100, Ki=5/20, Kd=200/500. DIFF=100~200
This reference value only for normal condition
,
according to the locale detail condition, each
reference value could be beyond the band.
4-6 Control specialities