5-3-4. Input terminal assignment
1. The number of high-speed counting channels of XG series PLC is shown in the following table:
PLC model
High speed counter channels
Incremental mode
AB phase mode
XG1
16 points
4
4
XG2
26 points
4
4
2. Definition of high-speed counting input terminal:
The meaning of each letter is:
U
A
B
Z
Counting pulse input
Phase A input
Phase B input
Z-phase pulse capture
Note: The Z-phase function is still under development.
Under normal circumstances, the input frequency of XG1 series high-speed counting terminal can reach 80kHz
and 50KHz in single-phase and AB phase modes respectively. The highest frequency of XG2 series high-speed
counting terminal can reach 200kHz in single-phase and AB phase modes. When the X input is not used as a
high-speed input port, it can be used as a common input terminal. In the frequency doubling item in the table,
"2" means fixed double frequency, "4" means fixed quadruple frequency, "2/4" means adjustable. The specific
port allocation and functions are shown in the following table:
XG1-16T4
Single phase incremental mode
AB phase mode
HSC0 HSC2 HSC4 HSC6 HSC8 HSC10 HSC12 HSC0 HSC2 HSC4 HSC6 HSC8
Max
frequency
80K
80K
80K
80K
50K
50K
50K
50K
Quadruple
frequency
2/4
2/4
2/4
2/4
Counting
interrupt
√
√
√
√
√
√
√
√
X000
U
A
X001
B
X002
U
A
X003
B
X004
U
A
X005
B
Phase B input
Phase A input