1~3
4. /CHGSTP signal is invalid only in this mode.
5. The segment number selection terminal can not only trigger the step change at the
edge, but also keep on state. This mode supports continuous and repeated triggering of a
certain segment. If the segment number selection terminal remains on, the motor stops
after encountering the overtravel signal, it is necessary to change the segment number
selection terminal to off, otherwise, the motor will execute the position segment after
the overtravel signal is cancelled.
6:
/PREFA(P5
-57)
/PREFB(P5
-58)
/PREFC(P5
-59)
Choose the
segment
through
terminal,
the range is
segment
1~8.
Note:
①
Firmware
version
3730 and
later
supports
1-8
segments of
step change
mode 6
②
Firmware
version
3740 and
later
supports
1-16
segments of
step change
mode 6
/PREFD
/PREFC
/PREFB
/PREFA
Segment no.
0
0
0
0
1 (segment 1 position)
0
0
0
1
2 (segment 2 position)
0
0
1
0
3 (segment 3 position)
0
0
1
1
4 (segment 4 position)
0
1
0
0
5 (segment 5 position)
0
1
0
1
6 (segment 6 position)
0
1
1
0
7 (segment 7 position)
0
1
1
1
8 (segment 8 position)
1
0
0
0
9 (segment 1 position)
1
0
0
1
10 (segment 2 position)
1
0
1
0
11 (segment 3 position)
1
0
1
1
12 (segment 4 position)
1
1
0
0
13 (segment 5 position)
1
1
0
1
14 (segment 6 position)
1
1
1
0
15 (segment 7 position)
1
1
1
1
16 (segment 8 position)
Note: the rising edge of P5-35 step change signal triggers each position (the rising edge
is invalid during operation).
1. When the servo enable is off during a certain section of operation, the motor stops
according to the servo off shutdown mode. After the shutdown, the positioning is
invalid.
2. The adjustment time is not valid in this mode.
3. After each operation completion, positioning completion and positioning approach
signal are all effective.
4. After the segment number is selected, the rising edge of P5-35/CHGSTP step change
signal is required to trigger to run the position segment, and the step change triggering
during segment operation is invalid.
5. Segment number selection terminal logic is voltage level valid. Input high voltage
level is valid, input low voltage level is invalid.
The following input signal can switch the segment 1 to 3 or 1 to 16:
Parameter Signal
name
Default
setting
Suitable
mode
Setting range
Modify
Effective
P5-57
/PREFA
internal
position
segment 1
n.0000
5
Range
0000-001A,
distribute to input terminal
through P5-57
Anytime At once
P5-58
/PREFB
internal
position
segment 2
n.0000
5
Range
0000-001A,
distribute to input terminal
through P5-58
P5-59
/PREFC
internal
position
segment 3
n.0000
5
Range
0000-001A,
distribute to input terminal
through P5-59
P5-60
/PREFD
n.0000
5
Range 0000-001A,
Содержание DS5K Series
Страница 1: ...DS5K series servo driver User manual WUXI XINJE ELECTRIC CO LTD Data No SC5 03 20200217 1 1...
Страница 2: ......
Страница 6: ......
Страница 107: ...3 Set the auto tuning interface 4 Click ok to start inertia identification...
Страница 114: ...3 set the auto tuning interface 4 click ok to estimate the inertia...
Страница 116: ...6 Start auto tuning 7 Wait for the end of the auto tuning...
Страница 120: ...with higher rigidity 6 Start auto tune 7 Open the servo enable then click ok...
Страница 186: ...Appendix 9 Torque speed characteristic curve...
Страница 187: ......
Страница 188: ......