gain parameters at the exit time. If auto-tuning fails, it is necessary to initialize the driver before
auto-tuning again.
Panel alarm in auto-tuning process
Error code
Meaning
Reasons
Err-1
Failure to search for optimal gain
Too large inertia ratio; too weak rigidity of
mechanism
Err-2
Overtrip alarm in auto-tuning process
Please make sure that there is no overrun
and alarm before auto-tuning.
Err-6
Driver is not in "bb" state at the time of
operation
Please make sure the present status of
driver
Err-7
Driver alarmed in auto-tuning process
The driver alarm occurs
XinJeServo software auto-tuning steps
1.
click auto-tuning on the XinJeServo software main interface
2.
set the auto-tuning trip in jog mode or manually