ADSL2+ Tester 4 Navigating the Displays
72-0046-03A 49
Fig 27:
“
Distance
”
results menu
Caution:
After setting
“
Function
”
item as
“
DMM
”
, directly pressing
“
AUTO TEST
”
key
can start a DMM test.
Pay attention to the measurement range descriptions in
“
Reference
”
menu of
the tester to ensure not to connect the out-ranged signals.
If one auto test is started and a signal with its voltage (>2V) is detected by the
tester,
“
Loop Resistance
”
,
“
Loop Capacitance
”
and
“
Isolation
Resistance
”
can not be measured and with no readings on the displays.
If one auto test is started and
“
Loop Resistance
”
is less than 40K
Ω
,
“
Loop
Capacitance
”
and
“
Isolation Resistance
”
can not be measured.
In
“
Loop Resistance
”
,
“
Loop Capacitance
”
and
“
Isolation Resistance
”
testing mode, the test can not be performed if there is a signal with its voltage
(>2V) is detected in the line.
The results in
“
Distance
”
menu are described in Table 20.
Item
Option
Description
Measurement
Unit
Metric, Imperial
Unit for the measurement figures.
Line
Diameter
Metric (mm): 0.4, 0.5, 0.6, 0.9
Imperial (AWG): 26, 24, 22, 19
Refer to Table 21 and 22.
Loop
Resistance or
Capacitance
——
Same as the readings in
“
Test Result
”
menu.
Distance
——
Distance=Loop Resistance (Capacitance) /
Resistance (Capacitance) constants
Table 20: Distance estimation
Result s
[
DISTANCE
]
Measur ement [ METRIC]
Line Diamet er [0.4]mm
Loop Resist ance >40.00k
Ω
Dist a nce >10.00km
TEST
RESULT
DIST
i
R u n n i n g . P l e a s e v i e w r e s u l t s
REF ERE