ADSL2+ Tester 3 Manipulation
72-0046-03A 17
•
Switch off the tester firstly.
•
Open the end cover of the tester.
•
Connect RS232 interface of the tester to PC serial port with RS232 communication
cable (supplied).
•
Switch on the tester.
•
Set RS232 port state to
ON
in
“
Others
”
menu.
•
Run the TestManagerPro software on PC, click
“
Select
”
button to choose the tester
’
s
type and click
“
Connect
”
button. After the successful connection, the user can upload,
view, analyze, delete, print test results in the form of report and do other operations.
•
Switch off the tester after communication with PC.
•
Pull out the RS232 communication cable.
Warning:
Be sure not to plug and unplug the communication cable alive when
connecting PC serial interface to the tester using the serial communication
cable, and be sure to ground or use ESD wrist strip. Plug and unplug the
communication cable alive may result in damage to PC or the serial interface
of the tester.
3.5.2
Upgrading the Embedded Software
Manufacturer will launch the latest version embedded software and host software
TestManagerPro in the website of our company for the users to download. Make sure to
visit our website frequently to ensure you will always get the software of latest version.
For the software upgrading method, please refer to the relevant part of
“
Communication
with PC
”
and follow instructions of the TestManagerPro.
Caution:
When performing the embedded software upgrading, in order to prevent the
instrument powered off caused by the battery exhausted, it is strongly
recommended to use external AC power supply to power the tester.
3.6
Rechargeable Batteries and Charge
The rechargeable batteries will typically power the tester for more than 2.5 hours with the
backlight and testing mode selected. The tester uses 5 high-performance 2300mAH Nickel
Metal Hydride (NiMH) rechargeable batteries placed in the battery case that may not be fully
charged when the user receives the tester. Whatever the state of charge, use the tester until
the battery is completed exhausted before giving it its first charge. This will ensure better
accuracy from the battery charge indicator.