Network Configuration
WorkCentre 6400 Multifunction Printer
System Administrator Guide
33
Raw TCP/IP Printing
Raw TCP/IP is a printing method used to open a TCP socket-level connection over Port 9100, to stream
a print-ready file to the printer's input buffer. It then closes the connection either after sensing an End
Of Job character in the PDL or after expiration of a preset time-out value. Port 9100 does not require
an LPR request from the computer or the use of an LPD running on the printer. Raw TCP/IP printing is
selected in Windows as the Standard TCP/IP port.
Basic Settings
Notes:
•
TCP/IP must be enabled before Raw TCP/IP Printing is enabled.
•
Raw TCP/IP printing is selected in Windows 2000 as the Standard TCP/IP port.
•
If your printer is locked, you must log in as a system administrator. For details, see
Accessing CentreWare IS
on page 17.
1.
In CentreWare IS, click
Connectivity
>
Protocols
>
Raw TCP/IP Printing
.
2.
Select
Enabled
to enable the protocol.
3.
Ensure that the
TCP Port Number
is set to 9100 for
Port 1
.
Note:
To emulate HP JetDirect EX Plus 3, set
Port 2
to 9101 and
Port 3
to 9102.
4.
Select
Enabled
for bidirectional communication.
5.
Ensure that
Maximum Connections per port (1-32)
for each port is set to the default value of 8.
6.
Set the
End of Job Timeout
to the desired number of seconds between 0 and 1800 before
processing a job with an
End of Job
character. The default time is 300 seconds.
7.
Select
Enabled
for
PDL Switching
to allow the printer to automatically switch between multiple
supported PDLs within a single job.
Note:
PDL Switching should normally be disabled.
8.
Click
Apply
. To set all fields to printer default values, click
Default All
.
9.
Click
OK
.
Advanced Settings
Additional Raw TCP/IP Printing options can be specified in the Advanced page. These include:
1.
Connections
•
Total Job Limit per Connection
: Type a value between 0 and 32768 to limit the number of
jobs that can be active for each port.
•
Maximum concurrent connections
.
•
Maximum concurrent jobs
: Type a value between 0 and 500 to specify the maximum
number of concurrent jobs. A setting of 0 allows unlimited concurrent jobs.
2.
Job Boundary Determination
•
Enable
Control D Marks End of PostScript Job
if you want the Control D character to be used
to indicate the end of a PostScript print job.
Содержание WorkCentre 6400S
Страница 12: ...Introduction WorkCentre 6400 Multifunction Printer System Administrator Guide 12...
Страница 20: ...Initial Setup WorkCentre 6400 Multifunction Printer System Administrator Guide 20...
Страница 52: ...Network Configuration WorkCentre 6400 Multifunction Printer System Administrator Guide 52...
Страница 92: ...Printing WorkCentre 6400 Multifunction Printer System Administrator Guide 92...
Страница 98: ...Managing Copy Functions WorkCentre 6400 Multifunction Printer System Administrator Guide 98...
Страница 118: ...Scanning WorkCentre 6400 Multifunction Printer System Administrator Guide 118...
Страница 168: ...Administrator Tools WorkCentre 6400 Multifunction Printer System Administrator Guide 168...
Страница 172: ...Customization and Expansion WorkCentre 6400 Multifunction Printer System Administrator Guide 172...
Страница 173: ...A WorkCentre 6400 Multifunction Printer System Administrator Guide 173 Audit Log Event Identification Numbers...
Страница 176: ...Audit Log Event Identification Numbers WorkCentre 6400 Multifunction Printer System Administrator Guide 176...
Страница 184: ...Index WorkCentre 6400 Multifunction Printer System Administrator Guide 184...